3OM-1075-002.pdf - 第81页
• • • • • Placement Coordinates and Angles (Z=Theta) Fig. 3B128 (2) Creation of Operation Data • • • • • P .C.B. Data T able 3B18 P .C.B. size X [mm] (Horizontal) 335.00 [ m m ] Y [mm] (V ertical) 255.00 [ m m ] T (Thick…

3. Example of Pattern Program Creation
Described on the following pages are the examples of pattern programs
to be created.
The examples are based on "TIM-X100R".
The placement coordinate reference for "TIM-X100F" is "Front
Right".
• Single Pattern
• Single Pattern (P.E.C. Recognition Function Enabled)
• Repetitive Pattern
• Repetitive Pattern (Unit P.C.B. B.B.R. Enabled)
• Repetitive Pattern (Block Sorting Enabled)
• Repetitive Pattern (Polar Coordinate Conversion Function)
• Multi-Model Repetitive Pattern
3.1 Single Pattern
(1) Information on Pattern Program Creation
••
••
• P.C.B. Size
Fig. 3B126
••
••
• Packaged Posture and IDs of Components
Fig. 3B127
No. Component ID
*1 TANA3216B0---
*2 TR2012-3B0SANL2
*3 S0P008-B02SAN
0206-003 2-61
AHB01EDTP
3. Example of Pattern Program Creation

••
••
• Placement Coordinates and Angles (Z=Theta)
Fig. 3B128
(2) Creation of Operation Data
••
••
• P.C.B. Data
Table 3B18
P.C.B. size
X [mm] (Horizontal) 335.00 [mm]
Y [mm] (Vertical) 255.00 [mm]
T (Thickness) 1.6 [mm]
P.C.B. origin offset
X [mm] (Horizontal) +00.000[mm]
Y [mm] (Vertical) +00.000[mm]
Z=theta (Angle) +00°000’
P.C.B. height offset +00.000[mm]
Pre-Placed P.C.B. top 0.00 [mm]
cmpnt thickness P.C.B. bottom 0.00 [mm]
Placement mode Placement
P.C.B. positioning reference Rear Left
P.C.B. locate Datum Outline
3.1 Single Pattern
0206-003 2-62 AHB01EDTP

••
••
• P.E.C. Recognition Data
Set "Disable" in the "P.E.C. recognition function" text box.
Do not set any other parameters.
••
••
• P.E.C. Recognition Mark Data
Do not create this data.
••
••
• Setup Data
Create this data when the automatic setup function should be used.
(3) Creation of Placement Feeder Location Data
Tabl 3B19
Fdr.No. Component ID C Comment
Dual Feeder Feeder Alternate
Fdr. No. Fixed Alternate Fdr. No.
101 TANA3216B0--- - - Disable Disable 000
103 TR2012-3B0SANL2 - - Disable Disable 000
105 S0P008-B02SAN E Disable Disable 000
(4) Creation of Placement Data (P-data) U01
••
••
• Unit Control
Tabl 3B20
Unit Control Offset X [mm] Offset Y [mm] Offset Z Offset H
Placement +00.00 +00.00 +00°00’ +0.00
••
••
• Unit P.C.B. B.B.R.
Set "Disable" in the "P.E.C. recognition mode Image" text box.
Do not set any other parameters.
••
••
• Placement Data (P-data)
Tabl 3B21
P-No. X [mm] Y [mm] Z H [mm] Fdr. No. C S HD PU
Comment V
1X
1
Y
1
000°00’ +0.00 101 - - 2 0 00
2X
2
Y
2
090°00’ +0.00 115 - - 1 0 00
3X
3
Y
3
180°00’ +0.00 105 - - 2 0 00
4 000.00 000.00 000°00’ +0.00 000 E - 0 0 00
(5) Creation of Placement Data (O-data) U01
Do not create this data.
3.1 Single Pattern
0206-002 2-63 AHB01EDTP