3OM-1075-002.pdf - 第81页

• • • • • Placement Coordinates and Angles (Z=Theta) Fig. 3B128 (2) Creation of Operation Data • • • • • P .C.B. Data T able 3B18 P .C.B. size X [mm] (Horizontal) 335.00 [ m m ] Y [mm] (V ertical) 255.00 [ m m ] T (Thick…

100%1 / 357
3. Example of Pattern Program Creation
Described on the following pages are the examples of pattern programs
to be created.
The examples are based on "TIM-X100R".
The placement coordinate reference for "TIM-X100F" is "Front
Right".
Single Pattern
Single Pattern (P.E.C. Recognition Function Enabled)
Repetitive Pattern
Repetitive Pattern (Unit P.C.B. B.B.R. Enabled)
Repetitive Pattern (Block Sorting Enabled)
Repetitive Pattern (Polar Coordinate Conversion Function)
Multi-Model Repetitive Pattern
3.1 Single Pattern
(1) Information on Pattern Program Creation
P.C.B. Size
Fig. 3B126
Packaged Posture and IDs of Components
Fig. 3B127
No. Component ID
*1 TANA3216B0---
*2 TR2012-3B0SANL2
*3 S0P008-B02SAN
0206-003 2-61
AHB01EDTP
3. Example of Pattern Program Creation
Placement Coordinates and Angles (Z=Theta)
Fig. 3B128
(2) Creation of Operation Data
P.C.B. Data
Table 3B18
P.C.B. size
X [mm] (Horizontal) 335.00 [mm]
Y [mm] (Vertical) 255.00 [mm]
T (Thickness) 1.6 [mm]
P.C.B. origin offset
X [mm] (Horizontal) +00.000[mm]
Y [mm] (Vertical) +00.000[mm]
Z=theta (Angle) +00°000’
P.C.B. height offset +00.000[mm]
Pre-Placed P.C.B. top 0.00 [mm]
cmpnt thickness P.C.B. bottom 0.00 [mm]
Placement mode Placement
P.C.B. positioning reference Rear Left
P.C.B. locate Datum Outline
3.1 Single Pattern
0206-003 2-62 AHB01EDTP
P.E.C. Recognition Data
Set "Disable" in the "P.E.C. recognition function" text box.
Do not set any other parameters.
P.E.C. Recognition Mark Data
Do not create this data.
Setup Data
Create this data when the automatic setup function should be used.
(3) Creation of Placement Feeder Location Data
Tabl 3B19
Fdr.No. Component ID C Comment
Dual Feeder Feeder Alternate
Fdr. No. Fixed Alternate Fdr. No.
101 TANA3216B0--- - - Disable Disable 000
103 TR2012-3B0SANL2 - - Disable Disable 000
105 S0P008-B02SAN E Disable Disable 000
(4) Creation of Placement Data (P-data) U01
Unit Control
Tabl 3B20
Unit Control Offset X [mm] Offset Y [mm] Offset Z Offset H
Placement +00.00 +00.00 +00°00’ +0.00
Unit P.C.B. B.B.R.
Set "Disable" in the "P.E.C. recognition mode Image" text box.
Do not set any other parameters.
Placement Data (P-data)
Tabl 3B21
P-No. X [mm] Y [mm] Z H [mm] Fdr. No. C S HD PU
Comment V
1X
1
Y
1
000°00’ +0.00 101 - - 2 0 00
2X
2
Y
2
090°00’ +0.00 115 - - 1 0 00
3X
3
Y
3
180°00’ +0.00 105 - - 2 0 00
4 000.00 000.00 000°00’ +0.00 000 E - 0 0 00
(5) Creation of Placement Data (O-data) U01
Do not create this data.
3.1 Single Pattern
0206-002 2-63 AHB01EDTP