3OM-1075-002.pdf - 第294页
The component storage box is used to store the rejected compo- nents in the component recognition processing. Fig. 3E60 When the component storage box is shifted toward the lower right directiion (viewed from the top), p…

2.1.8.1 "Component Reject" Tab
• Sheet Layout
When the "Component Reject" tab is pressed in the "Unit Offset" tab
sheet, the following tab sheet appears.
Fig. 3E59 "Component Reject" Tab Sheet
(Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options
are selected.
• Sheet Composition
*1 Offset Items
Set the following offset values.
Component storage box B X [mm] (Horizontal), Y [mm] (Ver-
tical), and L [mm] (Height)
Set the offsets to adjust the positional and vertical (height direc-
tion) deviations, compared with the design dimensions (position)
of the component storage box located at the center between
Feeder Bases #3 and #4. The values based on the PL-XY coordi-
nate system must be entered in each text box.
2.1 "Offset Data" Tab
0308-003 5-61 AHB01EDTP
*1

The component storage box is used to store the rejected compo-
nents in the component recognition processing.
Fig. 3E60
When the component storage box is shifted toward the lower right
directiion (viewed from the top), plus values must be enterd in the
"X [mm] (horizontal)" and "Y [mm] (vertical)" text boxes.
When the level (height) of the box is set lower than the design
value, a plus value must be entered in the "L [mm]" text box.
0206-002 5-62
AHB01EDTP
2.1 "Offset Data" Tab

2.1.8.2 "Vibratory Stick Feeder" Tab
• Sheet Layout
When the "Vibratory Stick Feeder" tab is pressed in the "Device Off-
set" tab sheet, the following tab sheet appears.
Fig. 3E61 "Vibratory Stick Feeder" Tab Sheet
The tab sheet may look different, depending on which options
are selected.
• Sheet Composition
*1 Offset Items
Set the following offset values.
Unit 1 to 6 X [mm] (Horizontal), Y [mm] (Vertical)
This offset data is used to adjust the positional deviations compared
with the design dimensions of Vibratory Stick Units #1 through #6.
The values based on the PL-XY coordinate system must be en-
tered in each text box.
Fig. 3E62
2.1 "Offset Data" Tab
0308-003 5-63 AHB01EDTP
*1