operation-cp45.pdf - 第113页

T ransfer & Installation Pr ocedur e 5-5 Figur e 5-2. Installation of Monitor and Signal T ower 8. Remove Clamp X (including the urethane cushion). Figur e 5-3. Method of Removing Clamp X 9. Then remove Clamp Y (incl…

100%1 / 324
Samsung Component Placer CP-45F(V)/FS Operations Manual
5-4
Figure 5-1. Height Adjustment of Equipment - Use a spanner supplied
5. Ensure the level surface by placing a leveling device on top of the feeder base and
L/M guide of Y1 axis.
6. I
n
stall the keyboard, mouse, and mouse pad on the front upper cover after leveling the
surface, and then install the teaching box.
7. Install the monitor and signal tower.
Caution
If the machine is not level, the level of machine precision
could be affected.
Be sure to keep the machine level and check if the feet are
tightened properly.
Caution
If two monitors are placed side by side, the life span of
monitors could be affected.
Leave an interval of 30 cm or more between two monitors.
Transfer & Installation Procedure
5-5
Figure 5-2. Installation of Monitor and Signal Tower
8. Remove Clamp X (including the urethane cushion).
Figure 5-3. Method of Removing Clamp X
9. Then remove Clamp Y (including the urethane cushion).
Caution
If the machine is operated when the clamp X, Y has not
been removed, the machine could be damaged.
Be sure to remove the clamp X, Y before supplying power.
Samsung Component Placer CP-45F(V)/FS Operations Manual
5-6
Figure 5-4. Method of Removing Clamp Y
10. Remove cable ties bound to the Z-axis, if necessary.
11. S
upply air pressure to the main air inlet.
Figure 5-5. Air Pressure Supply to the Main Air Inlet
12. Adjust air pressure to about 5 bars by turning the handle of a regulator.
13. Ensure the equipment power is properly connected according to the conditions for
your usage.
14. Measure the voltage value of your power supply with voltmeter and adjust to
equipment power condition.
15. The plug of power supply cable shall be connected to the outlet installed circuit
breaker in your company.
Caution
If the machine is operated when the cable Ties tied up to
the Z axis has not been removed, the machine could be
damaged.
Be sure to remove the cable ties tied up to the Z axis before
supplying power.