PCB Edit Command 11 - 9 Figur e 1 1-10. Scr een showing second point teaching for Array PCB Offset T each the origin of the Array PCB on the position that can determine the offset. When the Enter key is pressed after tea…

100%1 / 324
Samsung Component Placer CP-45F(V)/FS Operations Manual
11-8
Enter the number of Array PCBs as follows.
X=3
Y=2
<Count Direction> option button group
Select a method of numbering Array PCBs.
XDir
인경
123
4
56
YDir
인경
135
2
46
<Offset> edit box group
This value is used to set the offset value of the origin of Array PCB
automatically.
<Teach> button
This button is used to teach the offset value of Array PCB in the same way as
teaching the PCB size. When this button is clicked on, the following screens
are displayed in succession.
Figure 11-9. Screen showing first point teaching for Array PCB Offset
Teach the origin of Array PCB 1. When the Enter key is pressed after
teaching, the following screen is displayed.
When the X Direction is selected When the Y Direction is selected
PCB Edit Command
11-9
Figure 11-10. Screen showing second point teaching for Array PCB Offset
Teach the origin of the Array PCB on the position that can determine the
offset. When the Enter key is pressed after teaching, the following screen is
displayed.
Figure 11-11 Screen showing completion of Array PCB Offset Teaching
Press the Enter key to complete the Array PCB offset value teaching
operation.
<Apply> button
Automatically creates Array PCB data with the value set in this group
<5. Add Value> group
Set the values of X, Y, and R to be added to the grid line of the <1. Array> group.
When the Add button is clicked on after setting the desired values, the values
are added to the corresponding grid lines.
<OK> button
Saves the edited data and closes the screen..
<Cancel> button
Closes without saving the edited data.
<Fiducial Mark…> button
If there is a fiducial mark on the PCB, set the position of the fiducial mark and mark
data. When this button is clicked on, the following dialog box is displayed.
Samsung Component Placer CP-45F(V)/FS Operations Manual
11-10
Figure 11-12. Fiducial Position & Mark dialog box(When the Position Type is None)
<1. Position Type> combo box
Select the number of fiducial marks. Available numbers are as follows.
None: No fiducial mark.
1 Panel: 1 fiducial mark for PCB correction.
2 Panel: 2 fiducial marks for PCB correction.
3 Panel: 3 fiducial marks for PCB correction.
4 Panel: 4 fiducial marks for PCB correction.
1 Array: 1 fiducial mark for Array PCB correction in each Array PCB.
2 Array: 2 fiducial marks for Array PCB correction in each Array PCB.
3 Array: 3 fiducial marks for Array PCB correction in each Array PCB.
4 Array: 4 fiducial marks for Array PCB correction in each Array PCB.
<2. Mark Position> group