Features and Scope of Equipment 1-7 1.3. Mechanical Specifications 1.3.1. Size and weight of the equipment  Length  Including Cover: 1,660mm  Excluding projection of Conveyor Unit: 1,502mm  W idth: 1,540mm  Height …

100%1 / 324
Samsung Component Placer CP-45F(V)/FS Operations Manual
1-6
1.2.4.2. The pick & place cycle time for each model
Table 1-5. The pick & place Cycle Time for Each Model
Classification CP-45FV Remarks
Chip
0.197sec / component
(1608)
QFP
0.75 sec / component
(Flying Vision)
1.6 sec / component
(Stage Vision)
Connector
0.5 sec / component
(Flying Vision)
1.6 sec / component
(Stage Vision)
Simultaneous pickups under the optimum
conditions
Note) In the case of micro chips, lower it to
a proper speed by reducing the speed or
adjusting the delay variable according to the
placement status.
.Based on the optimum condition of QFP 80
(Y100mm, 100mm)
. Based on the optimum condition of black,
same interval, symmetrical type,
(Y 100mm , X 100mm)
The above are for the pick & place cycle time under the optimum conditions (rounded-off
to 1msec). In actual placement, the conditions that determine the cycle time may vary
depending on many factors such as the type of components, size of PCB, placement
position, etc. For more detailed information, please contact our Business Department or
C/S Center.
Memo
Features and Scope of Equipment
1-7
1.3. Mechanical Specifications
1.3.1. Size and weight of the equipment
Length
Including Cover: 1,660mm
Excluding projection of Conveyor Unit: 1,502mm
Width: 1,540mm
Height
Up to the upper surface of cover: 1,408mm
Up to the upper surface of monitor: 1,760mm
Up to the upper surface of tower lamp: 1,945mm
Weight: 1,150 kg
1.3.2. Requirements for air pressure
Pressure: 4.5 ~ 5.5 kgf/
Air Consumption: 150 N /min
Dry Air: air dew point of -17 or less
1.3.3. Environmental conditions
During operation
Temperature: +10 ~ +35
Humidity
Less than 50% RH (35)
Less than 90% RH (20)
During shipment or storage (in states other than during operation)
Temperature: -10 ~ +60
Humidity: 20% RH ~ 90% RH (non-condensation state)
Samsung Component Placer CP-45F(V)/FS Operations Manual
1-8
1.3.4. Noise
The CP-45F/V and the CP-45FS machine has a noise level not exceeding 80 dB with the
front and rear covers closed. The noise is measured at the upper surfaces of the front and
rear feeder bases while operating the equipment at 100% speed and driving all x-axis, y-
axis, and z-axis to the maximum stroke.
1.4. Electrical Specifications
1.4.1. Power requirements
Voltage
Single phase AC 220V ± 10 %
AC 100V / 110V / 120V / 200V / 220V/ 230V / 240V (shall be changed the
terminal of the transformer)
Power Consumption: 2.6 KVA (Maximum)
Frequency: 50 / 60 Hz
Figure 1-3. The solution for switching the power terminal connection of a transformer