PCB Edit Command 1 1-19 the current position of the XY axis.  <Device> combo box T o move or to read in the position of the XY axis, select the corresponding device. A vailable devices are as follows. Move Cam: Se…

100%1 / 324
Samsung Component Placer CP-45F(V)/FS Operations Manual
11-18
Use it to select or check the use of bad mark.
<2. Position Type> combo box
Select the position of bad mark. Available positions of bad marks are as follows.
None: No bad mark.
Array: 1 bad mark in each array PCB.
<3. Inspection Device> combo box
Select the device for bad mark inspection. Available devices are as follows.
Vision: Recognizes with the move camera in the head block.
<4. Mark Position> group
When <Position Type> is not None, data is generated according to the selected
<Position Type>. The number of data generated is as follows.
When the <Position Type> is Array: 1
When the <Position Type> is Panel: The number of Array PCBs
For example, when Array is selected in <Position Type>, the following dialog
box is displayed. (When the number of Array PCBs is 4)
Figure 11-15. Bad Mark Position dialog box(When the Position Type is Panel)
<No> column
A serial number of bad mark data.
<X> column
The X position value of the bad mark.
<Y> column
The Y position value of the bad mark.
<5. Teach> group
Used to move the XY axis of the equipment to the specified position or to read in
PCB Edit Command
11-19
the current position of the XY axis.
<Device> combo box
To move or to read in the position of the XY axis, select the corresponding
device. Available devices are as follows.
Move Cam: Selects the teaching camera.
Head1: Selects Head1.
Head2: Selects Head2.
Head3: Selects Head3.
Head4: Selects Head4.
Head5: Selects Head5.
Head6: Selects Head6.
<Move> button
Moves the XY axis to the device selected in <Device>. Before executing
Move, the cell in the grid corresponding to the desired position must be
clicked on with a mouse.
<Get> button
Reads in the current position of the XY axis of the device selected in
<Device>. Before executing, Get, the cell in the grid corresponding to the
desired position must be clicked on with a mouse.
<6. Logic> group
Select the color of bad mark. Available colors of bad marks are as follows.
Black: the mark looks darker than the surroundings.
White: the mark looks lighter than the surroundings.
<7. Offset> group
Used to set the offset value between bad marks automatically.
<X> edit box
Set the offset value of X.
<Y> edit box
Set the offset value of Y.
<Teach> button
Teach the offset value of bad mark by using the same method as teaching the
PCB size. When this button is clicked on, the following screens are displayed
in succession.
Samsung Component Placer CP-45F(V)/FS Operations Manual
11-20
Teach the first position of the bad mark. When the Enter key is pressed
after teaching, the following screen is displayed.
Teach the position of the neighboring bad mark. When the Enter key is
pressed after teaching, the following screen is displayed.
Press the Enter key to complete the bad mark offset value teaching
operation.
<Apply> button
Automatically creates the bad mark position data by using the offset value set
in this group.
<8. Camera No.> combo box
Select the camera to search the bad mark. At present, it is fixed to Move
Camera.
<9. Search Area> group
Set the area in which to search the bad mark. The main purpose of this feature is
to limit the search range for when there are forms similar to the mark near the
mark such that they can interfere with recognition on certain PCBs.
<Width X> edit box
Set the value of search range in X axis direction. In general, it is 6 mm.
<Width Y> edit box
Set the value of search range in Y axis direction. In general, it is 6 mm.