operation-cp45.pdf - 第321页
ANC Command 16-3 <Name> edit box Set the name of ANC. <Installed> group In the case of installing the ANC on the feeder base, set the feeder base and lane to install. The group is activated only for the g…

Samsung Component Placer CP-45F(V)/FS Operations Manual
16-2
To move or to read in the position of the XY axis, select the corresponding device.
Available devices are as follows.
Move Cam: Selects Teaching Camera.
Head1: Selects Head1.
Head2: Selects Head2.
Head3: Selects Head3.
Head4: Selects Head4.
Head5: Selects Head5.
Head6: Selects Head6.
<Move> button
Moves the XY axis to the device selected in the <Device>. The positions to move to
are the positions of fiducial mark and each nozzle hole.
<Get> button
Reads in the current position of the XY axis of the device selected in the <Device>.
At this time, the position to be read is the position of the fiducial mark. The position
of each nozzle hole can be read with the “Get” button.
<Move Next> button
When this button is clicked on, moves the device selected in the “Device” to the next
hole of the currently selected hole of the ANC.
<Shutter On/Off> button
When this button is clicked on, the ANC shutter is turned on or off.
<No real motion> check box
When this button is checked, manipulates the data for pick and put functions without
actual operation.
<Pick> button
When this button is clicked on, picks up the nozzle in the currently selected hole of
the ANC. Select the head to pick in the “Device”.
<Put> button
When this button is clicked on, puts the nozzle in the head selected in the “Device” to
ANC.
<Put all nozzle> button
When this button is clicked on, puts the nozzles in all the heads to the ANC.

ANC Command
16-3
<Name> edit box
Set the name of ANC.
<Installed> group
In the case of installing the ANC on the feeder base, set the feeder base and lane to
install. The group is activated only for the gripper ANCs.
<Feeder Base> combo box
Select the feeder base to install the ANC.
<Lane No.> edit box
Set the lane number of the feeder base to install the ANC.
<Fiducial Mark Detail …> button
Set the fiducial mark data. When this button is clicked on, the following dialog box is
displayed.
For the explanation of this dialog box, please refer to [PCB Edit].
<Hole Position Detail …> button
Set the position of each hole of the ANC. When this button is clicked on, the
following dialog box is displayed.

Samsung Component Placer CP-45F(V)/FS Operations Manual
16-4
<Grid> group
Displays the position of each hole.
<Hole – Define> column
Displays the hole number.
<Position - X> column
Displays the X position of the hole
<Position - Y> column
Displays the Y position of the hole.
<Position - Z> column
Displays the Z position of the hole.
<Position - R> column
Displays the R position of the hole.
<ANC Hole Position Version> combo box
ANC 의 종류에 따라서 ANC 의 각 홀의 위치들을 자동으로 설정할 수
있도록 해 줍니다. 현재 설치되어있는 ANC 의 종류에 맞게 선택하십시