operation-cp45.pdf - 第48页

Samsung Component Placer CP-45F(V)/FS Operations Manual 1-10  Protect Module 1.4.3.2. Hardware  W indows 98  CPU Intel Celeron™ over 733MHz  Over 40GB of HDD, IDE  Hard Disk Rack  Over 64MB of memory  CD-ROM 48x …

100%1 / 324
Features and Scope of Equipment
1-9
The equipment power is properly connected according to the conditions for usage prior to
the shipment.
1.4.2. E
PU (External Programming Unit)
1.4.2.1. Software
EPU System Software
Protect Module
1.4.2.2. Hardware
Windows 98
CPU Intel Celeron™ over 733MHz
Over 10.2GB of HDD, IDE
Over 64MB of memory
CD-ROM 48x
3.5 inch FDD lea
Keyboard: Mini Keyboard (86 keys)
Mouse: Serial Mouse or PS/2 mouse
1.4.2.3. Display
Programming Monitor: 14 inch VGA Color (1024 × 768 dots)
1.4.3. HLC (Host Line Computer)
1.4.3.1. Software
VME, Windows 98
Danger
If unspecified voltage is used or power input is changed
improperly, fire could occur and a death from electric shock
could occur.
Change of power input must be done by a trained repair
and maintenance operator or our authorized C/S
personnel.
Memo
Samsung Component Placer CP-45F(V)/FS Operations Manual
1-10
Protect Module
1.4.3.2. Hardware
Windows 98
CPU Intel Celeron™ over 733MHz
Over 40GB of HDD, IDE
Hard Disk Rack
Over 64MB of memory
CD-ROM 48x
3.5 inch FDD lea
Keyboard: Mini Keyboard (86 keys)
Mouse: PS/2 mouse
1.4.3.3. Display
Programming Monitor: 14 inch VGA Color (1024 × 768 dots)
Teaching Monitor: 14 inch VGA Color (800 x 600 dot)
The specifications of the equipment can be altered without prior notice to improve the
product performance.
Memo
Features and Scope of Equipment
1-11
1.5. Control System Specifications
Embedded in the CP-45F/V and the CP-45FS is a high-speed CPU that provides the
production and production management information of PCB, and is designated for
creating and editing the production program as well. The system operation can reading be
learned by using the MMI based on Windows 98.
1.5.1. PCB production
Program selection
The CP-45F/V and the 45FS has large-capacity hard disk (over 10.2 GB). Data can
also be stored in a 3.5-inch floppy disk. The user can store the program or data either
in a hard disk or a floppy disk.
Continuous production of PCB
The number of completed PCB's produced is shown on the screen while PCB's are
being produced. The number of PCB's to be produced and the number of components
to be placed can be inputted, and the number of PCB's currently being produced on
the production management page can be shown on the screen.
Test driving functions
The correct coordinates of a component position can be obtained by temporarily
placing the component and inputting the correct coordinates through a teaching box
by tracking the position with a camera. In this case, the coordinates are adjusted
relative to each other.
Production management information
The CP-45F/V and the CP-45FS provides the following basic production
management information:
Number of completed PCB's
Operating time (actual running time)
Stop time
Number of successfully placed components
Number of bad-marked PCB's
Number of components supplied from each feeder