operation-cp45.pdf - 第164页

Samsung Component Placer CP-45F(V)/FS Operations Manual 11-10 Figur e 1 1-12. “ Fidu cial Position & Mark ” dial og box(When the Positi on T ype is “ None ” )  <1. Position T y pe> combo box Select the number …

100%1 / 324
PCB Edit Command
11-9
Figure 11-10. Screen showing second point teaching for Array PCB Offset
Teach the origin of the Array PCB on the position that can determine the
offset. When the Enter key is pressed after teaching, the following screen is
displayed.
Figure 11-11 Screen showing completion of Array PCB Offset Teaching
Press the Enter key to complete the Array PCB offset value teaching
operation.
<Apply> button
Automatically creates Array PCB data with the value set in this group
<5. Add Value> group
Set the values of X, Y, and R to be added to the grid line of the <1. Array> group.
When the Add button is clicked on after setting the desired values, the values
are added to the corresponding grid lines.
<OK> button
Saves the edited data and closes the screen..
<Cancel> button
Closes without saving the edited data.
<Fiducial Mark…> button
If there is a fiducial mark on the PCB, set the position of the fiducial mark and mark
data. When this button is clicked on, the following dialog box is displayed.
Samsung Component Placer CP-45F(V)/FS Operations Manual
11-10
Figure 11-12. Fiducial Position & Mark dialog box(When the Position Type is None)
<1. Position Type> combo box
Select the number of fiducial marks. Available numbers are as follows.
None: No fiducial mark.
1 Panel: 1 fiducial mark for PCB correction.
2 Panel: 2 fiducial marks for PCB correction.
3 Panel: 3 fiducial marks for PCB correction.
4 Panel: 4 fiducial marks for PCB correction.
1 Array: 1 fiducial mark for Array PCB correction in each Array PCB.
2 Array: 2 fiducial marks for Array PCB correction in each Array PCB.
3 Array: 3 fiducial marks for Array PCB correction in each Array PCB.
4 Array: 4 fiducial marks for Array PCB correction in each Array PCB.
<2. Mark Position> group
PCB Edit Command
11-11
If <Position Type> is not None, the number of data corresponding to the
number of fiducial marks selected are generated. For example, when 2 Panel is
selected, the following dialog box is displayed.
Figure 11-13. Fiducial Position & Mark dialog box(When the Position Type is 2
Panel)
<No> column
A serial number of the position of fiducial mark.
<X> column
The X position value of fiducial mark.
<Y> column
The Y position value of fiducial mark.
<Mark> column
The mark ID value of fiducial mark. This value must be set from a series of
numbers in <5. Mark List>.
<3. Inspection Device> combo box
Select the device to inspect the fiducial mark. Available devices are as follows.
Vision: Recognizes with the move camera in the head block.
<4. Teach> group
Used to move the XY axis of the equipment to the specified position or to read in
the current position of the XY axis.
<Device> combo box
To move the XY axis or to read in the position, select the corresponding
device. Available devices are as follows.
Move Cam: Selects Teaching Camera.