operation-cp45.pdf - 第216页

Samsung Component Placer CP-45F(V)/FS Operations Manual 11-62 F i g u r e 1 1 - 4 0 “ Align T ype = V ision, Package Gr oup = User IC, Algorithm = Odd with L e a d ” dialog box  <Offset X> edit box Set the offs et…

100%1 / 324
PCB Edit Command
11-61
Set the lead parameter and lead group. Please refer to <11.1.15.1 Lead
Parameter>, and <11.1.15.2 Lead Group>.
<Option> group
Set the align option data.
<Area Margin> edit box
Set the limit for the image to be off the center of the screen when the component
is recognized. For example, if this value is 5mm, then the image of the
component should be within 5mm of the center of the screen.
<Lead Type> combo box
Select the lead type. Available lead types are as follows.
Gull-Wing: Leads protrude outward as QFP.
J-Lead: Leads roll inward as PLCC.
<Algorithm> combo box
Select the algorithm to recognize the component. Available algorithms are as
follows.
Black Body: Method to process IC types fast. In general, applied to IC types.
All Body: Applied to various types of components, but it takes long to process.
Applied to non IC types or hard to recognize components.
Odd with No Lead: Applied to odd type components without leads.
Odd with Lead: Applied to odd type components with leads.
When <Algorithm> is Odd with No Lead or Odd with Lead, the following
dialog box is displayed.
Samsung Component Placer CP-45F(V)/FS Operations Manual
11-62
Figure 11-40 Align Type = Vision, Package Group = User IC, Algorithm = Odd with
Lead dialog box
<Offset X> edit box
Set the offset value between the component centroid and the actual
component center in X direction.
<Offset Y> edit box
Set the offset value between the component centroid and the actual
component center in Y direction.
<Offset R> edit box
Set the offset value between the angle of the main axis of the component and
the actual angle.
<Filter Perimeter> edit box
Set the value to remove noise in the component vision image. If the
perimeter of the object in the image is smaller than this value, it is processed
as noise.
<Filter Area> edit
Set the value to remove noise in the component vision image. If the area of
the object in the image is smaller than this value, it is processed as noise.
<Threshold> edit box
When there is a pre-treatment process for component recognition and the
gray level image is converted into binary, it is the value used as the criteria to
determine black and white.
The value range is 0 – 255(0: black, 255: white), and this value serves to
differentiate the component from the background. When the set value is 0,
the value is set automatically during component recognition.
<Auto Threshold> check box
Check it to set the <Threshold> value automatically.
PCB Edit Command
11-63
<Outline> button
Displays the outline of the component on the vision monitor by using the set align
data.
<Move…> button
Performs component pickups or moves to the fix camera.
<Test> button
Performs the component recognition test by using the set align data.
11.1.15.1. Lead Parameter
Set the lead parameter for User ICs. Possible lead parameters are up to 8.
Figure 11-41. Screen showing Lead Parameter setting in the dialog box for User IC Lead
Parameter & Group
<Lead Parameter> group
Set the lead parameter.
<No.> column
Displays the lead parameter number. Possible range is 0 – 7.
<Width Typ> column
Set the lead width.
<Width Max> column
Set the lead width including the highest tolerance.
<Width Min> column
Set the lead width including the lowest tolerance.
<Length Typ> column
Set the lead length.
<Length Max> column