Sys.Setup Command 15-13 Set the X position of the corresponding user dump box. <Grid - Y> column Set the Y position of the corresponding user dump box. <Grid – Release Z> column Set the Z axis height of t…

Samsung Component Placer CP-45F(V)/FS Operations Manual
15-12
Figure 15-9. “Sys. Setup : Dump Box” dialog box
<System Default Dumpbox> group
Set the data on the system dump box provided by the System as a default. 2 system
dump boxes are installed on the conveyor guide located close to the front of the
equipment as a default.
<Position X, Y – Front Left(1)> edit box
Set the position of the system dump box 1(Located on the left of the conveyor
guide).
<Position X, Y – Pre Dump> edit box
Set the position on which the head block stops before dumping.
<Release Z Height> edit box
Set the Z axis height of the head at the time of dumping.
<Part Dump Conveyor> group
The position of the part dump conveyor is set to default. If the position of the part
dump conveyor is needed to change, check <Use> check box and teach its new
position.
<User Define Dumpbox> group
Set the data on the user dump box installed by the user. The maximum number of
dump boxes that can be set by the user is 5.
<Grid - No> column
Displays the user dump box number.
<Grid - Use> column
Set whether to use the corresponding user dump box or not.
<Grid - X> column

Sys.Setup Command
15-13
Set the X position of the corresponding user dump box.
<Grid - Y> column
Set the Y position of the corresponding user dump box.
<Grid – Release Z> column
Set the Z axis height of the head at the time of dumping to the corresponding user
dump box.
<Device> combo box
To move or to read in the position of the XY and Z axes, select the corresponding
device. Available devices are as follows.
Move Cam: Selects Teaching Camera.
Head1: Selects Head1.
Head2: Selects Head2.
Head3: Selects Head3.
Head4: Selects Head4.
Head5: Selects Head5.
Head6: Selects Head6.
<Move> button
Moves the XY and Z axes to the device selected in <Device>. At this time, the edit
box corresponding to the position to move to must be clicked on with a mouse.
<Get> button
Reads in the current position of the XY and Z axes of the device selected in <Device>.
At this time, the edit box corresponding to the position to be read must be clicked on
with a mouse.
<Update> button
Transmits the set data to the equipment and closes the dialog box.
<Cancel> button
Ignores the set data and closes the dialog box.
15.8. Camera [F8]
Sets various data on the camera and performs camera calibration.

Samsung Component Placer CP-45F(V)/FS Operations Manual
15-14
Figure 15-10. “Sys. Setup : Camera Setting – Move Camera” dialog box
<Select> combo box
Select the camera type to set. Available camera types are as follows.
Move Camera : Camera used for position teaching or fiducial mark check.
Fix Camera : Camera used for component check, it is fixed on the feeder lane.
Fly Camera : Camera used for component check, it is attached to each head.
<Camera No> option button
Selects the camera number for each camera type.
For the move camera, no.1, for the fix camera, nos. 1-3, and for the fly camera nos.1-
6 can be selected.
Above screen is the case where the camera type is set to “Move Camera”.