ANC Command 16-5 오 . ANC-W38*L406-37Hole. ANC-W34*L41 1-37Hole. <Device> combo box To move or to read in the position of XY, Z, and R axes, select the corresponding device. Available devices are as follows. M…

Samsung Component Placer CP-45F(V)/FS Operations Manual
16-4
<Grid> group
Displays the position of each hole.
<Hole – Define> column
Displays the hole number.
<Position - X> column
Displays the X position of the hole
<Position - Y> column
Displays the Y position of the hole.
<Position - Z> column
Displays the Z position of the hole.
<Position - R> column
Displays the R position of the hole.
<ANC Hole Position Version> combo box
ANC 의 종류에 따라서 ANC 의 각 홀의 위치들을 자동으로 설정할 수
있도록 해 줍니다. 현재 설치되어있는 ANC 의 종류에 맞게 선택하십시

ANC Command
16-5
오.
ANC-W38*L406-37Hole.
ANC-W34*L411-37Hole.
<Device> combo box
To move or to read in the position of XY, Z, and R axes, select the corresponding
device. Available devices are as follows.
Move Cam: Selects Teaching Camera.
Head1: Selects Head1.
Head2: Selects Head2.
Head3: Selects Head3.
Head4: Selects Head4.
Head5: Selects Head5.
Head6: Selects Head6.
<Move> button
Moves the XY, Z, and R axes to the device selected in the <Device>. At this time,
the column corresponding to the position to move to must be clicked on.
<Get> button
Reads in the current position of the XY, Z, and R axes of the device selected in
the <Device>. At this time, the column corresponding to the position to be read
must be clicked on.
<Fiducial Mark – Pos.1> edit box
Set the position of fiducial mark1.
<Fiducial Mark – Pos.2> edit box
Set the position of fiducial mark2.
<Update> button
Saves the set data and closes the dialog box.
<Cancel> button
Ignores the set data and closes the dialog box.
<Update> button
Saves the set ANC data and closes the dialog box.
<Cancel> button

Samsung Component Placer CP-45F(V)/FS Operations Manual
16-6
Ignores the set ANC data and closes the dialog box.
Warning
When Manual ANC movement is executed, the nozzle of
the head and other areas of the machine might collide
unless the programmed nozzle and the actual nozzle
coincide. Be sure to match the programmed nozzle and
the actual nozzle in the machine.