operation-cp45.pdf - 第213页
PCB Edit Command 1 1-59 Please refer to “ 1.2.15 Setting the User IC Component data ” . 11.1.15. User IC component data setting Set align data for User IC components. First, the basic concept behind User IC com ponent da…

Samsung Component Placer CP-45F(V)/FS Operations Manual
11-58
Set the size of the whole component in Y direction.
<Body X> edit box
Set the size of component body in X direction.
<Body Y> edit box
Set the size of component body in Y direction.
<Lead Width> edit box
Set the width of lead.
<Lead Pitch> edit box
Set the lead pitch.
<Lead Foot> edit box
Set the length of the lead that touches the surface.
<Lead Length> edit box
Set the length of the lead shown in the align camera.
<Align Z> edit box
Set the height for recognition. Based on the component surface, if the top is to be
recognized, set - value and if the bottom is to be recognized, set + value.
<Option> group
Set the align option data.
<Area Margin> edit box
Set the limit for the image to be off the center of the screen when the component
is recognized. For example, if this value is 5mm, then the image of the
component should be within 5mm of the center of the screen.
<Tolerance Tangential> edit box
Set the allowable tolerance when the lead is pushed to the side. Set it with a
percentage against <Lead Pitch>.
<Outline> button
Displays the outline of the component on the vision monitor by using the set align
data.
<Move…> button
Performs component pickups or moves to the fix camera.
<Test> button
Test component recognition by using the set align data.
<Auto Teach> button
Finds out the component align data automatically.
11.1.13. Connector-1 component data setting
Set the align data for Connector-1 components.
Please refer to “1.2.15 Setting the User IC component data”.
11.1.14. Connector-2 component data setting
Set the align data for Connector-2 components.

PCB Edit Command
11-59
Please refer to “1.2.15 Setting the User IC Component data”.
11.1.15. User IC component data setting
Set align data for User IC components.
First, the basic concept behind User IC component data setting is explained. Please refer
to the next figure.
Whole Data
Register overall
information on
the component.
Lead Parameter
Data that have Lead
information on lead forms
Lead Group
Data that specify the
position where the lead
are converged.
Lead Gap
Information on the
position of empty in the
lead group
Figure 11-38. The basic concept of User IC component data setting
User IC component data has one whole data.
User IC component data has up to 16 lead groups.
User IC component data has equal or fewer lead parameters than the lead groups(up
to 8).
Each lead group must specify 1 corresponding lead parameter.
Each lead group has up to 4 lead gaps.

Samsung Component Placer CP-45F(V)/FS Operations Manual
11-60
Figure 11-39. “Align Type = Vision, Package Group = User IC” dialog box
<Camera No.> combo box
Select the camera to recognize the component.
<Light Control> button
Set the light for the camera to recognize the component.
<Size & Etc> group
Set the align size.
<Body X Typical> edit box
Set the size of component body in X direction.
<Body X Max> edit box
Set the maximum size of component body in X direction.
<Body X Min> edit box
Set the minimum size of component body in X direction.
<Body Y Typical> edit box
Set the size of component body in Y direction.
<Body Y Max> edit box
Set the maximum size of component body in Y direction.
<Body Y Min> edit box
Set the minimum size of component body in Y direction.
<Align Z> edit box
Set the height for recognition. Based on the component surface, if the top is to be
recognized, set - value and if the bottom is to be recognized, set + value.
<Lead Parameter & Group> button