Chapter 14. Diagnosis Command
The Diagnosis command is composed of 6 submenus: I/O, Conveyor, Light, Vacuum,
Jogbox, and Tray.
This commands performs a module test on each part.
When a submenu of the <Diagnosis> command is selected, the corresponding dialog box
is displayed on the screen. While the corresponding dialog box of the submenu is
displayed, selecting the menu again activates the dialog box.
Figure 14-1. When the Diagnosis command is selected
Figure 14-2. Submenus of the Diagnosis command
14.1. I/O [F2]
The <I/O> command sets or displays the status of various I/O (input/output) sensors on
the equipment.
When this button is clicked on, the following dialog box is displayed.
Samsung Component Placer CP-45F(V)/FS Operations Manual
14-2
Figure 14-3. Diagnosis : I/O Status dialog box
<Output> group
Select the output block to display. There are 3 blocks in total for output.
<Prev Block>
button
Displays the previous block of the current block.
<Next Block>
button
Displays the next block of the current block.
<Input> group
Select the input block to display. There are 2 blocks in total for input.
<Prev Block>
button
Displays the previous block of the current block.
<Next Block>
button
Displays the next block of the current block.
<Output Status> group
Display the sensor status of the selected output block. Red indicates on status, and
blue indicates off status.
Selecting the sensor to set and double clicking on the left button of a mouse or
pressing the space bar reverses the sensor status.
<Input Status> group
Display the sensor status of the selected input block. Red indicates on status, and blue
indicates off status.
Diagnosis Command
14-3
<Feeder base Check> button
Turns on or off the air pressure solenoid of the feeder base. The operation status of air
pressure solenoid can be checked.
<Work zone Run> button
<Close> button
Closes the dialog box.
14.2. Conveyor [F3]
Checks the status of various devices in the conveyor group.
When this button is clicked on, the following dialog box is displayed.
Figure 14-4. Diagnosis : Conveyor dialog box
<Grid> group
<Operation> column
Displays the operation list of devices to check.
Place Stopper Up: Checks the up motion of the stopper in the operation area..
Place Stopper Down: Checks the down motion of the stopper in the operation
area..
BackUp Table Up: Checks the up motion of the backup table that supports the
bottom of the PCB.
BackUp Table Down: Checks the down motion of the backup table that supports
the bottom of the PCB.
Hole Fixture Up: Checks the up motion of the hole fixture that arranges PCBs.