operation-cp45.pdf - 第147页

V iew Commands 9-7 Figur e 9-4. “ Manual T ools – Head block ” dial og box  <V acuum level> group T urn on/of f the air pressure of each head.  <Camera Select> group Set the light value of the fiducial came…

100%1 / 324
Samsung Component Placer CP-45F(V)/FS Operations Manual
9-6
Hole Fixer: A method of arrangement by inserting pins in the holes of the
PCB.
Edge Fixer: A method of arrangement by pushing the PCB from the side with
a device attached to the conveyor.
Edge Fixer2: It is the same as the Edge Fixer method, but it is a method of
arrangement by pushing twice from the side.
<PCB In> button
Loads the PCB in the operation area. Before executing this function, the PCB
arrangement method must be set in <Fix Type>.
<PCB Unlock> button
Releases the PCB fixed in the operation area.
<PCB Out> button
Releases the PCB in the operation area to the next machine.
9.1.3. Head block Dialog Box
Used to turn on/off the air pressure of each head, set the light value of each camera,
open/close the mirror of the head block, and put all nozzles.
View Commands
9-7
Figure 9-4. Manual Tools – Head block dialog box
<Vacuum level> group
Turn on/off the air pressure of each head.
<Camera Select> group
Set the light value of the fiducial camera, fly camera, and upward camera.
<Head Inspection> group
<Move all head to align height> button
Move the Z axis of the head to the Align height to test the head.
<Mirror Open/Close> button
Open or Close the Mirror.
<Real Display/Binary> button
Displays the actual image and the processed image (binary) on the vision
screen.
<Nozzle Put All> button
Puts all Nozzles.
9.1.4. Camera Dialog Box
It tests the status of each camera through the vision monitor according to the image grab
and lighting
Samsung Component Placer CP-45F(V)/FS Operations Manual
9-8
Figure 9-5. Manual Tools – Camera dialog
9.2. Current Position
<Position Window> command displays the current position of each axis and the name of
the nozzle installed on the head in real time. When this command is selected, the
following window is displayed on the MMI main screen.