CM602all_EJM8AESM_Service Manual.pdf - 第1016页
8 6 7 5 • Remove the relay connector. • Remove the earth cable and the driver- holding screws, and then the driver. Item Direct Tray Remark • Pull the box towards you so that the driver can be removed easily. Remove the …

4
Remove the control-box front cover.
• Remove the box-holding screws.
3
Remove the control-box front cover.
Remark
2
Turn off the power switch.
Remove the lift-axis driver.
• Remove all the connectors from the
front of the control box and from the
board.
• Remove the cable tie from the front of
the control box.
Tray
1
Item
Direct Tray
EJM8A-E-SMA070205-A01-00
Page 7-2-5-2

8
6
7
5
• Remove the relay connector.
• Remove the earth cable and the driver-
holding screws, and then the driver.
Item
Direct Tray
Remark
• Pull the box towards you so that the
driver can be removed easily. Remove
the driver connectors.
Tray
• Remove the two screws from the upper
front side of the box.
Ref. Side
Ref. Side
EJM8A-E-SMA070205-A01-00
Page 7-2-5-3

Check the driver parameters.
11
9
Item
• Check the driver parameters.
• Open the driver-operation-panel cover.
Referring to the operation method and
the parameter list from the next page
onward, check and set the driver
parameters.
Remark
Direct Tray
• Replace the driver. Install the driver
and connect the connectors in reverse
order to Steps 3 to 8.
* Connect the correct connectors,
checking the connector labels.
• After connecting the connectors, turn
on the power.
10
Tray
EJM8A-E-SMA070205-A01-00
Page 7-2-5-4