CM602all_EJM8AESM_Service Manual.pdf - 第733页
Optional Accessory Parts Replacement Remarks Nozzle Changer Unit (8-nozzle type) Item Disconnect the nozzle changer cables. Nipper Cable tie 150 mm 4 pcs. J1 ■ 35= Open, J1 ■ 36= Closed ■ =AF-2 AR-4 BF-B BR-D Remove the …

Optional Accessory Parts Replacement
Remarks
Switch off the main power.
Turn the switch left.
Close the cock of the MR unit.
After closing the cock, turn the regulator
left to remove air.
* Left gauge: Forcible blow
Middle gauge: Bulk air
Right gauge: Main air
From 0.49MPa
to 0.54MPa
Remove the feeder cover and the chute.
Allen key 3 mm
Phillips screwdriver #2
Screw M4 2 pcs.
Screw M4 x 10mm 3 pcs.
Thick washer 3 pcs.
Remove the right side cover.
Phillips screwdriver #2
Truss screw M4 4 pcs.
Nozzle Changer Unit (8-nozzle type)
3
4
1
Item
2
1
2
EJM8A-E-SMA060103-A01-00
Page6-1-3-2

Optional Accessory Parts Replacement
Remarks
Nozzle Changer Unit (8-nozzle type)
Item
Disconnect the nozzle changer cables.
Nipper
Cable tie 150 mm
4 pcs.
J1
■35= Open, J1■36= Closed ■=AF-2
AR-4
BF-B
BR-D
Remove the nozzle changer.
Allen key 4 mm
Screw M5 x 25 3 pcs.
Iron plate
Allen key 3 mm
Screw M4 x 8 mm 1 pc.
Disconnect the nozzle changer connectors.
Place the iron plate on the bottom of the head.
5
6
7
8
EJM8A-E-SMA060103-A01-00
Page6-1-3-3

Optional Accessory Parts Replacement
Remarks
Nozzle Changer Unit (8-nozzle type)
Item
Install the nozzle changer.
Allen key 5 mm
Screw M6 x 25 3 pcs.
Thick washer 2 pcs.
Position the dial gauge.
Dial gauge
Magnetic stand
Parallelism:
Specifications:
0.02 mm or less
Connect the nozzle changer connectors.
J1■35= Open, J1■36=Closed ■=AF-2
AR-4
BF-B
BR-D
Adjust the nozzle changer to parallel.
9
10
11
12
EJM8A-E-SMA060103-A01-00
Page6-1-3-4