CM602all_EJM8AESM_Service Manual.pdf - 第920页

12 34 Remarks Carry out "Return to origin." Shuttle Tray Allen key 3 mm M4 x 10L 1 pc. Connect the door switch connector. 10 11 12 9 Close the maintenance door. Put the cover back on. Allen key 3 mm Phillips sc…

100%1 / 1093
Adjustable distance: +/- 3 mm
(The hole is 3-mm long.)
5
Tray Shuttle Tray
(Be sure to keep yourself off the drive section.)
Remarks
If it is necessary to adjust the distance more than 3 mm,
loosen the bolts below and move the belt.
Measure the distance from the dog
Item
Carry out "Return to origin."
6
If it is necessary to adjust the distance, loosen the bolts that are positioned
at the back of the belt clamp, and adjust the distance.
to the mechanical stopper.
Allen key 3 mm
Screw M4 2 pcs.
Allen key 3 mm
Screw M4 2 pcs.
Distance from Dog to
Stopper:
9.5mm±1mm
7
8
3 6.5 36.5(30)
4.5
731.5
727st
O/R
StrokeOrigin
O/R
Mechanical
stopper
Dog
soft limit soft limit
EJM8A-E-SMA070107-A01-00
Page 7-1-7-3
12
34
Remarks
Carry out "Return to origin."
Shuttle Tray
Allen key 3 mm
M4 x 10L 1 pc.
Connect the door switch connector.
10
11
12
9
Close the maintenance door.
Put the cover back on.
Allen key 3 mm
Phillips screwdriver #2
M4×8L     3 pcs.
M4×10L    2 pcs.
M5×Truss 15L  2 pcs.
switch connector.
Remove the jig from the door
Check the distance.
Item
Tray
30
B
A=727cm
(770)
C
D
E
Door switch of
Delivery position
EJM8A-E-SMA070107-A01-00
Page 7-1-7-4
carry out machine parameter teaching.
See Section 7-1-2. "Shuttle
Tray Pickup Position
Teaching."
13
Item Remarks
Shuttle Tray
Once the mechanical adjustment is complete,
Tray
EJM8A-E-SMA070107-A01-00
Page 7-1-7-5