CM602all_EJM8AESM_Service Manual.pdf - 第940页

Tray Shuttle Tray Item Remarks 9 Close the side cover. Phillips screwdriver #2 Screw M4 8 pcs. EJM8A-E-SMA070110-A01-00 Page 7-1-10-4

100%1 / 1093
Tighten the power locks of the motor
Tray Shuttle Tray
6
RemarksItem
5
Position the slit of the dog slit in the extension position.
Inch the extension-axis (One inching: 0.1mm)
See Section 7-1-2 "Shuttle
Tray Pickup Position
Teaching."
Carry out the 'Pickup position" teaching.
8
7
Allen key 4 mm
Screw M5 4 pcs.
Jig: FM-0982
Allen key 2.5 mm
Screw M3 2 pcs.
section.
Position the bearing with the jig.
+
-
A=436.5 st
Origin
E
CD
(454.5)
8
F
B=11.0
Shutter
(2)
(73)
Magazine side
(0.5)
Lift side
(1.0)
Light beam sensor
Extension position
PH sensor
 Dog
EJM8A-E-SMA070110-A01-00
Page 7-1-10-3
Tray Shuttle Tray
Item Remarks
9
Close the side cover.
Phillips screwdriver #2
Screw M4 8 pcs.
EJM8A-E-SMA070110-A01-00
Page 7-1-10-4
Tool
Min.
Teaching
10
kgs.
80
Part WeightTotal
30
Extension-Axis Timing Belt Replacement
Jig: FM-0982
Min.
40
Shuttle Tray
This section describes the procedures for replacing the extension-axis timing belt.
Jig
Tray
Removal/Disassembly Assembly/Adjustment
Min. Min.
7-1-11
Dange
r
Warning
Caution
EJM8A-E-SMA070111-A01-00
Page 7-1-11-1