CM602all_EJM8AESM_Service Manual.pdf - 第1027页
a stopper. Insert the Allen key into the ball screw again, using the front side of the bolt. Remove the wrench. Remove the coupling. Allen key 4 mm Wrench 13 and 19 mm M5 6 pcs. Remark 5 Direct Tray Keeping the wrench on…

the bolt shown with the arrow below.
coupling to the front.
Item
Return the lift-axis to the origin.
1
Direct Tray
Phillips screwdriver #2
M4 screw 11 pcs.
Allen key 2.5 mm
M3 4 pcs.
Remark
Rear
2
Turning the ball screw, move the
Insert an Allen key into the ball screw.
hold the nut with a wrench.
Holding the Allen key with one hand,
Remove the cover. Turn off the power. Remove the bolt.
Phillips screwdriver #2
M4 screw 4 to 6 pcs.
Open the cover.
Left. Stay at the front side when removing
Right
Tray
3
4
Ball screw
Wrench 5 mm
EJM8A-E-SMA070206-A01-00
Page 7-2-6-2

a stopper. Insert the Allen key into the ball screw again, using the front side of the
bolt. Remove the wrench. Remove the coupling.
Allen key 4 mm
Wrench 13 and 19 mm
M5 6 pcs.
Remark
5
Direct Tray
Keeping the wrench on the nut, remove the Allen key. Insert the bolt to be used as
Allen key 5 mm
Bolt M6 x 45
Item
7
8
Tray
Once the coupling has been removed, holding the stopper with one hand, and the
Allen key with the other, remove the stopper bolt. To avoid letting the ball screw and
the Allen key turn anticlockwise due to the weight of the lift table, hold the ball screw.
Turn the Allen key gradually to lower the lift to the lowest position.
Holding the lift with one hand, lower the lift to the lowest position by turning the Allen
key that prevents the ball screw from dropping.
Remove the motor connectors BLKTL,
TLM1 and ENTL1.
6
EC16CX
BLKTL
TLM1
ENTL1
Encoder
Brake
Power
source
Allen key 5
Bolt M6×45
Front of
bolt
End of ball screw
EJM8A-E-SMA070206-A01-00
Page 7-2-6-3

Remark
Remove the motor-holding screws. Turn the
motor so that the connector side faces forward.
Remove the motor, following the point below.
Install a new motor in the same way.
Put the coupling jig on. Position the motor
until the jig moves smoothly.
After positioning, fully tighten the motor
bolts and remove the jig.
Allen key 5 mm
M5 4 pcs.
Direct Tray
Tightening torque: 8.0N•m A=2 mm +/- 1 mm
Return the lift axis to the origin. (See Step 1.) Raise the lift with one hand, put the block gauge
(10 mm) on the stopper with the other. Lower the lift manually to sandwich the gauge.
Block gauge 10 mm
FM-0544: Centering jig
Allen key 5 mm
M5 4 pcs.
Torque wrench
Allen key 5 mm
Ruler 150 mm
M6 6 pcs.
12
Loosen the lift-axis motor coupling.
9
Item
10
11
Tray
10-mm block
gauge
Coupling
Motor
Ball screw
Origin: 10-mm
higher than the
mechanical stopper
Mechanical stopper
A
The amount of the right
and left gaps should be
the same.
Round
corner
Ball
screw
Lift
Connector
side
POINT
Using the lower
round corner of
the motor, move
the motor and pull
it out diagonally.
EJM8A-E-SMA070206-A01-00
Page 7-2-6-4