CM602all_EJM8AESM_Service Manual.pdf - 第916页
Item Remraks 21 Specifications: ±1.0 mm or less After tightening the coupling, confirm the height. Enter the measured value into [TL] manually. 22 Tray Shuttle Tray + - EJM8A-E-SMA070106-A01-00 Page 7-1-6-7

Lift will Fall!
When the coupling is loosened, the lift
will fall down. To avoid this, hold the
ball screw with a wrench.
After tightening the coupling,
remove the wrench.
RemraksItem
Specifications:
±1.0mm or less
When the difference in
height between the lift and
the replenishment tables is
+/- 1.0 mm or less,
proceed to Step 22 and
enter the parameter.
Measure the height of the jigs.
Reference: Jig on the replenishment table.
remove the coupling.
Allen key 4 mm
Wrench 14 mm
Screw M5 6 pcs.
Holding the ball screw with a wrench,
Measure the height of the jig.
Specifications:
±1.0 mm or less
Adjust the height of the lift table, turning the wrench.
Specifications:
Tightening torque:
8.0N・m
A=2mm±1mm
Allen key 5mm
Ruler 150mm
M6 6 pcs.
Tighten the lift-axis motor coupling.
20
19
18
17
Tray Shuttle Tray
Replenishment
table
Lift table
If the cover cannot be
removed
,
hold here.
Wrench
A
To
lower
To
raise
EJM8A-E-SMA070106-A01-00
Page 7-1-6-6

Item Remraks
21
Specifications:
±1.0 mm or less
After tightening the coupling, confirm the height.
Enter the measured value into [TL] manually.
22
Tray Shuttle Tray
+
-
EJM8A-E-SMA070106-A01-00
Page 7-1-6-7

Assembly/AdjustmentRemoval/Disassembly
15
Min. Min.
30
Total Part Weight
Phillips screwdriver #2
Allen key 3 mm
Ruler 150 mm
Ruler 300 mm
kgs.
45
Min.
Connector jig
7-1-7 Shuttle Head Stroke Adjustment
Shuttle Tray
Tools
Tray
・This section describes the procedures for adjusting the stroke of the shuttle head.
I Since this adjustment requires releasing the safety cover switch, only those who are authorized
to release it based on the Document "Key Switch/Key Disk Receipt Confirmation and Safety
Precautions" are permitted to perform this adjustment.
Jigs
Min.
Teaching
Danger
Caution
Warning
EJM8A-E-SMA070107-A01-00
Page 7-1-7-1