CM602all_EJM8AESM_Service Manual.pdf - 第206页

Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles) Remarks Item Select the stage to be taught. When using one nozzle, follow Steps 9 to 16. Press [Nozzle]. If using one nozzle, teach each nozzle separately. …

100%1 / 1093
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Item
Press [Unlock] and [Height org tch] simultaneously.
The head camera moves to the heat
calibration mark of that stage and
measures the height of each nozzle.
After the height of Nozzle 8 is measured,
the head stops moving down.
Press [Unlock] and [Jig remove] simultaneously.
The head moves to the nozzle setting
position.
Remove Nozzle 130 from
each nozzle position.
Press the "Return" key.
To save the machine
parameter, press the
[Return] key.
Press [Unlock] and [Run] simultaneously.
The X- and the Y- axes return to the
origin.
5
6
7
8
EJM8A-E-SMA040203-A01-00
Page 4-2-3-3
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Item
Select the stage to be taught.
When using one nozzle, follow Steps 9
to 16.
Press [Nozzle].
If using one nozzle, teach
each nozzle separately.
Press [Unlock] and [Return to origin] simultaneously.
The selected stage returns to the origin.
Press [Unlock] and [Jig setting] simultaneously.
Set Nozzle 130 on the
nozzle position displayed
on the screen.
9
12
11
10
EJM8A-E-SMA040203-A01-00
Page 4-2-3-4
Maintenance Adjustment Light Transfer-Head Assembly (8 nozzles)
Remarks
Item
Press [Unlock] and [Height org tch] simultaneously.
The head camera moves to the heat
calibration mark of that stage and
measures the height of that nozzle.
Follow Steps 5 and 6 for
Nozzle Positions 2 to 8.
Press [Unlock] and [Jig remove] simultaneously.
The head moves to the nozzle set
position (over the NG box).
Remove Nozzle 130.
Press the "Return" key.
To save the machine
parameter, press the
[Return] key.
Press [Unlock] and [Run] simultaneously.
The X- and the Y- axes return to the
origin.
16
13
14
15
EJM8A-E-SMA040203-A01-00
Page 4-2-3-5