CM602all_EJM8AESM_Service Manual.pdf - 第962页
7 bolts positioned at the rear side of the belt clamp section. If it is necessary to adjust the distance more than 3 mm, loosen the bolts below and move the belt. Carry out "Return to origin." Check the distanc…

Set the machine parameter offset to "0."
Measure the distance from the dog
to the mechanical stopper.
4
3
Remarks
Ruler
Gap from dog to stopper:
9.5mm
2
1
Item
Remove the top cover.
Carry out "Return to origin."
Phillips screwdriver #2
Truss M4 4 pcs.
Tray Shuttle Tray
5510(22)
3
558
550 cm
-O/R
StrokeOrigin
+O/R
Mechanical
stopper
Dog
+soft limit -soft limit
EJM8A-E-SMA070114-A01-00
Page 7-1-14-2

7
bolts positioned at the rear side of the belt clamp section.
If it is necessary to adjust the distance more than 3 mm,
loosen the bolts below and move the belt.
Carry out "Return to origin." Check the distance.
5
8
Allen key 2.5 mm
Screw M3 2 pcs.
Adjustable distance:
+/- 3 mm
Remarks
Allen key 2.5 mm
Screw M3 2 pcs.
Phillips screwdriver #2
Truss M4 4 pcs.
Put the top cover back on.
To adjust the distance, loosen the
Tray
Item
6
Shuttle Tray
22
B
A=550 cm
(587)
C
D
E
(67)
(8.5)
(46.5)
EJM8A-E-SMA070114-A01-00
Page 7-1-14-3

Item
9
Once the mechanical adjustment is complete,
carry out machine parameter teaching.
Remarks
See Section 7-1-2. "Shuttle
Tray Pickup Position
Teaching."
Shuttle TrayTray
EJM8A-E-SMA070114-A01-00
Page 7-1-14-4