Machinery Part Replacement Remark Turn off the power and air supply. Remove the head. See "12-Nozzle-Head-Unit Replacement." Section 5-10-1 Remove the tube and the cable tie. 12-Nozzle Head Unit 3 2 Item 1 Remo…

Machinery Part Replacement
This section describes the procedures for removing the upper frame and the Z-axis unit.
Tools
Allen key 3 mm
Nipper
Magic marker
Jig
None
12-Nozzle Head Unit
5-10-9 Removing the Upper Frame and the Z-axis Unit
Caution
Dange
r
Warning
EJM8A-E-SMA051009-A01-00
Page 5-10-9-1

Machinery Part Replacement
Remark
Turn off the power and air supply.
Remove the head.
See "12-Nozzle-Head-Unit
Replacement."
Section 5-10-1
Remove the tube and the cable tie.
12-Nozzle Head Unit
3
2
Item
1
Remove the two tubes.
Disconnect the connectors
CN35 and 36
Disconnect the connectors
CN39 and 40
<Left side>
1
2
EJM8A-E-SMA051009-A01-00
Page 5-10-9-2

Machinery Part Replacement
Remark
12-Nozzle Head Unit
Item
Magic marker
Nipper
Disconnect the connectors and the
tubes. Cut off the cable ties.
Nipper
Put a mark on the vacuum release tube and remove it.
Disconnect the connectors. Cut off the cable ties.
4
5
6
Disconnect the connectors
CN31 & 32.
Disconnect the connectors
CN29 & 30.
Disconnect the connectors
CN25 & 26.
Remove
the tube.
Disconnect the connector
CN4.
Disconnect the connector CN6.
Disconnect the connector
CN7.
Disconnect the valve connector.
Disconnect the valve connector.
Disconnect the θ motor connector
<Right side>
Put a mark
here.
EJM8A-E-SMA051009-A01-00
Page 5-10-9-3