CM602all_EJM8AESM_Service Manual.pdf - 第262页
Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles) ・ Tools None ・ Jig 5-hole Camera Teaching Jig (For Multi-purpose machines) This section describes the procedures for entering the offset for the origin of t…

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Item
The offsets are entered into the screen below: Specifications:
The newly measured offsets will be
entered automatically into the screen at
left.
Offset range:
Z=1.00 mm to 11.00 mm
If an offset is out of the
specification, check that:
1. the vacuum pressure is
not excessively low.
2. the nozzle is not worn.
3. the nozzle is set
properly.
4. the vacuum sensor
functions properly.
17
EJM8A-E-SMA040303-A01-00
Page4-3-3-6

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
・Tools
None
・Jig
5-hole Camera Teaching
Jig (For Multi-purpose
machines)
This section describes the procedures for entering the offset for the origin of the chip recognition camera theta axis.
4-3-4 Chip Recognition Camera --- Theta Axis Origin Offset
Remove the nozzle holders.
Remove the NG box.
Assembly
A
d
j
ustment
min.
Teaching
10min.
Total Time Weight of
Part
Removal
Disassembl
y
min.
10min. kgs
Caution
Dange
r
Warning
EJM8A-E-SMA040304-A01-00
Page 4-3-4-1

Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
Remarks
Press [Chip recog camera
θaxis OriginOffset].
If 0 is displayed in the
"Magnifying power" boxes
shown at left, enter a
tentative vale of 0.01.
Press [Chip recog camera
θaxis OriginOffset].
Select the stage to be taught.
Press [Unlock] and [Jig setting] simultaneously.
The head moves to the jig set position (to
the center of the stage).
Set the jig on Head 3.
1
Item
4
2
3
EJM8A-E-SMA040304-A01-00
Page 4-3-4-2