Option Part and Accessory Replacement Component-Thickness-Measuring Unit Remark Item 16 Press [UNLOCK] on the operation panel and [Run] simultaneously. 16 EJM8A-E-SMA060403-A01-00 Page 6-4-3-11

100%1 / 1093
Option Part and Accessory Replacement
Component-Thickness-Measuring Unit
Remark
Turn off (O) the servo switch.
Open the safety cover.
Remove the nozzle.
Close the safety cover.
Turn on (I) the servo switch. * Repeat Steps 2 to 14 for
the other tables.
Press the function key .
12
13
Press [UNLOCK] on the operation panel and [Jig remove] simultaneously.
14
15
Item
Each head
Gang
Each head
Gang
12
15
EJM8A-E-SMA060403-A01-00
Page 6-4-3-10
Option Part and Accessory Replacement
Component-Thickness-Measuring Unit
Remark
Item
16
Press [UNLOCK] on the operation panel and [Run] simultaneously.
16
EJM8A-E-SMA060403-A01-00
Page 6-4-3-11
• Tools
Phillips screwdriver #2
Allen key Long/Short
Nipper
• Jigs
FM-1962 (1) (2)
Component-thickness-
measuring-unit-optical-
axis-adjusting jig
(1. Component-height-
detection-sensor-
adjusting power box
2. Component-thickness-
measuring-unit-light-axis-
adjusting jig)
Component-Thickness-Measuring Unit
6-4-4 Component-Thickness-Sensor-Amplifier Replacement (8-Nozzle-Head Spec.)
Option Part and Accessory Replacement
This section describes the procedures for replacing the component-thickness-sensor amplifier
(8-nozzle-head specifications).
FM-1962(1) Component-thickness-measuring-unit-
light-axis-adjusting jig
(1. Component-height-detection-sensor-adjusting
power box )
FM-1962(2) Component-thickness-measuring-unit-
light-axis-adjusting jig
(2. Component-thickness-measuring-unit-light-axis-
adjusting jig)
Danger
Warning
Caution
EJM8A-E-SMA060404-A01-00 Page 6-4-4-1