CM602all_EJM8AESM_Service Manual.pdf - 第313页

(over the NG box). camera. Light Transfer-Head Assembly (3 nozzles) simultaneously. 4 Select the desired stage. Press [Unlock] and [Jig setting] 3 Lamp Value Range: 0 to 255 The head moves to the chip recognition Put the…

100%1 / 1093
Tools
Jig
FM-1136
Light Intensity Teaching
Jig
None
4-3-12 Light Intensity
Maintenance Adjustment Light Transfer-Head Assembly (3 nozzles)
This section describes the procedures for specifying light amount.
Weight of
Par
t
min. min.
Removal
Disassembl
y
A
ssembl
y
A
d
j
ustment
Teaching Total Time
Kgs
.
15 min.
15
min
.
Caution
Danger
Warning
EJM8A-E-SMA040312-A01-00
Page 4-3-12-1
(over the NG box).
camera.
Light Transfer-Head Assembly (3 nozzles)
simultaneously.
4
Select the desired stage.
Press [Unlock] and [Jig setting]
3
Lamp Value Range:
0 to 255
The head moves to the chip recognition
Put the jig onto Nozzle
Position 3.
Press [Unlock] and [Shadow light tch]
simultaneously.
The head moves to the jig setting positio
n
Item Remarks
Press [Lighting intensity].
2
1
Maintenance Adjustment
EJM8A-E-SMA040312-A01-00
Page 4-3-12-2
(over the NG box).
The head of the selected stage returns
to the origin.
Press the "Return" key.
Press [Unlock] and [Run]
simultaneously.
Light Transfer-Head Assembly (3 nozzles)
Item Remarks
simultaneously.
The head moves to the jig setting positio
n
Press [Unlock] and [Jig remove]
7
6
5
Maintenance Adjustment
Remove the jig from
Nozzle Position 3.
EJM8A-E-SMA040312-A01-00
Page 4-3-12-3