CP643 系统参考.pdf - 第166页

MODE 150-0-0 Command Pass: [AUTO] - [MODE] Press to select production, simulate or idle mode. Product: Regular operation is carried out. Simulate: Only the X-, Y-, and D-axes move. Part pick-up is not carried out. Idle: …

100%1 / 388
SPEED 130''-5-0
Command Pass: [AUTO] - [MARK EDITOR] - [SPEED]
This is used when slight changes or adjustments of the current position are required.
To command page 541.
Caution: The changes that were set while in the Mark Editor Mode, such as Mark Sequence Skip or other
manual input, are only valid for the board that is being produced. After that board production is
finished and the board has been unloaded, the machine automatically releases those settings and the
following boards will be produced under normal settings. Also, if a condition arises where it becomes
necessary to read that fiducial mark, it will be necessary to read the mark that was set to be skipped.
Revision History
RETURN 130''-6-0
Command Pass: [AUTO] - [RETURN]
This is used when wanting to exit Mark Editor. The cross hairs displayed on the screen disappear
and Editor is exited after the previous changes have been saved.
Revision History
SEQ. NO 140-0-0
Command Pass: [AUTO] - [SEQ. NO]
Press to input the sequence number from which operation is to be started.
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-5 CP643E System Reference
MODE 150-0-0
Command Pass: [AUTO] - [MODE]
Press to select production, simulate or idle mode.
Product: Regular operation is carried out.
Simulate: Only the X-, Y-, and D-axes move. Part pick-up is not carried out.
Idle: Continuous operation occurs without loader operation. Boards are not replaced
and image recognition is not performed.
Idle2: Continuous operation occurs with loader operation.
Boards are not replaced and image recognition is not performed.
Note: The production mode is automatically selected when the power supply is turned on.
Revision History
PRODUCT 151-0-0
Command Pass: [AUTO] - [MODE] - [PRODUCT]
Parts are picked up and placed on the boards. This is standard operation.
Revision History
SIMULATE 152-0-0
Command Pass: [AUTO] - [MODE] - [SIMULATE]
Parts are not picked up. The XY-table and the device tables operate as they do during production.
This mode is used for such things as verifying placing coordinates.
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-6 CP643E System Reference
IDLE 153-0-0
Command Pass: [AUTO] - [MODE] - [IDLE]
Continuous operation is performed without changing the board or performing vision processing.
The nozzles descend at stations 1 and 11. When using this mode, the feeders should be removed
from the tables.
Note: This mode should be used only for checking machine operation. It should not be used for production.
Revision History
IDLE 2 154-0-0
Command Path: [AUTO] - [MODE] - [IDLE2]
Continuous operation occurs with loader operation.
Boards are not replaced and image recognition is not performed. Nozzles are lowered at ST1 and
ST11. Operation should be performed with parts removed.
Note: The “Idle” mode is used only for checking machine operation. It is not used for production.
Revision History
CLEAR OFF / CANCEL 171-0-0
Command Pass: [AUTO] - [CLEAR OFF / CANCEL]
If CYCLE STOP is pressed the machine will stop after the current sequence is finished and the
display will return to command page 100.
If an error occurs the contents of the error are displayed in the second display area, production is
halted, and the RESET button is enabled. If RESET is pressed the display returns to command page
100.
CLEAR OFF: The message “Unloading...” displays in the first display area when this key is
pressed. After production of all boards in the machine is completed the RESET
button will be enabled.
CANCEL: The [CLEAR OFF] display changes to [CANCEL] when the clear off operation is
set. If this is selected the instruction for stopping after production of the boards in
the machine is complete will be canceled.
Revision History
V1.10 and later
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-7 CP643E System Reference