CP643 系统参考.pdf - 第305页

29: Width Max Limit 0.00 ~ 655.35 [mm] * This sets the maximum conveyor width value. Default: 460.00 mm 30: Width Min Limit 0.00 ~ 655.35 [mm] * This sets the minimum conveyor width value. Default: 50.00 mm 40: LMS Flag …

100%1 / 388
14: PCB_Location Corner: Pin #
This sets the method used to locate the board on the XY table.
Corner: Corner used as standard
Pin: Reference pin used as standard
When "Pin" is selected check to make sure that the reference pin is properly set in relation to
the board loaded onto the XY-table.
Default: "Corner”
20: Loader Status A 0000 0000 0000 0000 $
This sets board loader operating conditions (input as a 16 bit binary mask pattern).
Default: 0000 0000 0000 0000
Special mode Bit map Decimal
No IN1 Conveyor stopper 0000 0000 0010 0000 32
Use V 1.04 - Carry 0000 0000 0001 0000 16
Use V. 1.05 - Carry 0000 0000 0000 0000 0
21: Loader Status B 0000 0000 0000 0000 $
This sets board loader operating conditions (input as a 16 bit binary mask pattern).
Default: 0000 0000 0000 0000
22: Conveyor Type L -> R: R -> L *
This sets the direction of conveyor board flow.
L -> R: Left to right
R -> L: Right to left (Optional)
Default: L -> R.
23: Wait Signal Off: On $
This enables or disables the wait signal.
Default: "Off”
24: Busy Invalid No: Yes #
This is the setting for whether or not the machine refers to board request signals from the
previous stage.
No: Ignore board request signals and feed out boards when they become available.
Yes: Refer to board request signals
Default: "No”
25: Conveyor Control Manu: Auto #
This selects whether or not the conveyor width will be controlled automatically.
Manu: Manual conveyor adjustment
Auto: Automatic conveyor adjustment
Default: "Manu”
26: Conveyor Adj. Limit 0.05 ~ 1.00 [mm] #
This sets the limit to determine if fine adjustment of the conveyor width is required. Fine
adjustment is carried out if the difference between the current conveyor width and the
board width set in the program exceeds this limit.
Default: 0.50 mm
27: Conveyor Stop Offset 0.00 ~ 2.00 [mm] #
This sets the conveyor stop offset during conveyor width adjustment.
Default: 0.30 mm
28: Conveyor adj. Timer 0 ~ 120000 [msec] #
When performing automatic conveyor width adjustment this value sets the amount of time
that elapses before a time-up error occurs.
Default: 60000 msec
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-5 CP643E System Reference
29: Width Max Limit 0.00 ~ 655.35 [mm] *
This sets the maximum conveyor width value.
Default: 460.00 mm
30: Width Min Limit 0.00 ~ 655.35 [mm] *
This sets the minimum conveyor width value.
Default: 50.00 mm
40: LMS Flag Off: On #
This sets whether the unit will be a HELPS compatible machine or not.
Off: Not compatible
On: Compatible
Default: "Off"
41: Cell Status Unit: Active: Passive #
This is only valid for HELPS compatible machines. This sets the cell status.
Unit: Unit cell
Active: Active cell
Passive: Passive cell
Default: "Unit"
42: Change Over Mode 0 ~ 200 #
This is valid only for HELPS compatible machines. It sets the method of reporting the board
type.
Default: 0
43: Auto Start No: Yes $#
This is valid only for HELPS compatible machines. It sets the start-up method after
changeover has been completed.
No: Machine waits for START button to be pressed after changeover has finished.
Yes: Automatic start
Default: "No” ‘Automatic start’ is not currently supported.
44: Backup Plate Check No: Yes #
On HELPS compatible machines, this determines whether a backup plate check will be done
during changeover.
No: No backup plate changeover check.
Yes: Backup plate changeover check.
Default: "No"
45: Command Line Status RS232C: LAN: ETHERNET *
Default: “RS232C” (“LAN” and “ETHERNET” are not currently supported).
46: Command Line Port 0 ~ 30 #
Specify the port number on the 6-channel communications board when a RS232C cable is
being used.
0: Command line will not be used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-6 CP643E System Reference
47: ID Station Type S_type: A_type *
On HELPS compatible machines, this sets the location of the ID station.
S_type: The ID station is in the machine.
A_type: The ID station is outside the machine.
Default: "S_type”
48: Buzzer Warning On: Off #
On HELPS compatible machines, this sets whether or not a buzzer sounds during
changeover operator prompts.
On: Buzzer will sound.
Off: Buzzer will not sound.
Default: "On”
49: Process Timer 1 ~ 120000 [msec] #
On HELPS compatible machines, this sets the protocol timer value.
Default: 10000 msec
50: Reader Type 0 ~ 9 #
On HELPS compatible machines, when using a bar code reader, this sets the type of code
reader.
0: Bar code reader
1: Pattern code reader
Other: Bar code reader
Default: 0
51: Code Reader Timer 1 ~ 120000 [msec] #
This sets the amount of time allowed for a bar code reader to read a board type code.
Default: 10000 [msec]
52: Code Reader Retry 0 ~ 10 #
This sets the number of times a code reader will reread a board in case of a misreading the
first time.
Default: 0
53: Reader1 Port No. 0 ~ 30 #
Sets the 6-channel port number for code reader 1 (top surface).
0: Top surface code reader is not used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
54: Reader 2 Port No. 0 ~ 30 #
Sets the 6-channel port number for code reader 2 (bottom surface).
0: Bottom surface code reader is not used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
55: PCB Code Terminal Non: Use #
This sets whether or not a Handy Terminal is used for recovery.
Non: Not Used
Use: Used
Default: "Non"
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-7 CP643E System Reference