CP643 系统参考.pdf - 第346页

[Cause]: When the XY-table was raised to the board conveying position, the secondary rail clamper on the XY-table was unable to engage the secondary rail on the in and out-conveyors. [Remedy]: Adjust the position of the …

100%1 / 388
1.3 Alarms Which Prevent the Machine from Being Started
When it is not possible to start the machine, the cause will be displayed. Once the cause
has been removed the Press "START" message will automatically appear.
Cam Handle Alarm
[Cause]: The cam handle cannot be detected.
[Remedy]: Return the cam handle back to its original position.
Vacuum Alarm
[Cause]: The vacuum pressure has fallen below the standard level.
[Remedy]: Close the mechanical valves at each station and check the vacuum pump.
Air Pressure Alarm
[Cause]: The air pressure has fallen below the standard level.
[Remedy]: Check the air supply.
Safety Door, Front
Safety Door, Rear
Safety Door 1
Safety Door 2
[Cause]: Either the front door is open or one of the sensors at the rear of the
machine has been triggered.
[Remedy]: Close the door or remove the offending object.
Return Cam to Zero
[Cause]: The input of the cam axis zero position sensor cannot be recognized.
[Remedy]: Return the cam axis to it's zero position either by using the cam handle or
by inching.
Lifter Not at Lower Limit
[Cause]: The lifter is not at it's lowered position.
[Remedy]: Lower the lifter.
Parts not set
[Cause]: In device change mode the parts have not been set on the next device table.
[Remedy]: Set the parts.
Max D No. Error
[Cause]: In device change mode or in changeover mode the production program
calls for a device number greater than 70.
[Remedy]: Change the program so that it only calls for device numbers less than 70.
No Production Program
[Cause]: A valid program has not been transmitted to the machine or the program
has not been chosen.
[Remedy]: Transmit a valid program to the machine or choose a program.
No Proper
[Cause]: Valid Proper data has not been transmitted to the machine.
[Remedy]: Transmit valid Proper data to the machine.
No Status
[Cause]: Valid Status data has not been transmitted to the machine.
[Remedy]: Transmit valid Status data to the machine.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-17 CP643E System Reference
[Cause]: When the XY-table was raised to the board conveying position, the
secondary rail clamper on the XY-table was unable to engage the
secondary rail on the in and out-conveyors.
[Remedy]: Adjust the position of the secondary rail clamper on the XY-table.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-18 CP643E System Reference
1.4 Alarms Which Prevent RETURN and Shut-down
Vision System Alarm
[Cause]: The vision processing system is hung.
[Remedy]: Reboot the machine. If it appears to reboot normally, survey the situation
before proceeding. If it does not reboot normally, and the alarm occurs
again, the vision processing board is probably defective.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-19 CP643E System Reference