CP643 系统参考.pdf - 第347页
1.4 Alarms Which Prevent RETURN and Shut-down Vision System Alarm [Cause]: The vision processing system is hung. [Remedy]: Reboot the machine. If it appears to reboot normally, survey the situation before proceeding. If …

[Cause]: When the XY-table was raised to the board conveying position, the
secondary rail clamper on the XY-table was unable to engage the
secondary rail on the in and out-conveyors.
[Remedy]: Adjust the position of the secondary rail clamper on the XY-table.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-18 CP643E System Reference

1.4 Alarms Which Prevent RETURN and Shut-down
Vision System Alarm
[Cause]: The vision processing system is hung.
[Remedy]: Reboot the machine. If it appears to reboot normally, survey the situation
before proceeding. If it does not reboot normally, and the alarm occurs
again, the vision processing board is probably defective.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-19 CP643E System Reference

Notes:
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-20 CP643E System Reference