Interlock alarm: I_CRRY Remove board from I_LIFT [Cause]: • With a board on the in-lifter, an attempt was made to advance the in- carrier but whether a board was clamped on the in-carrier was unknown. If a board with par…

Cylinder cycle alarm: I_LIFT
Up/down movement of the I_LIFT time up
[Cause]: • The in-lifter was raised but the upper limit sensor did not come ON
within the designated amount of time.
• The in-lifter was lowered but the lower limit sensor did not come ON
within the designated amount of time.
• The in-lifter upper limit/lower limit sensors were both ON.
[Remedy]: • Confirm that the in-lifter up/down operation is working smoothly.
• Make sure that the upper/lower limit sensors are installed in the correct
positions.
• Confirm that the upper/lower limit sensors come ON and go OFF
correctly during the in-lifter up/down operation.
Cylinder cycle alarm: O_LIFT
Up/down movement of the O_LIFT time up
[Cause]: • The out-lifter was raised but the upper limit sensor did not come ON
within the designated amount of time.
• The out-lifter was lowered but the lower limit sensor did not come ON
within the designated amount of time.
• The out-lifter upper limit/lower limit sensors were both ON.
[Remedy]: • Confirm that the out-lifter up/down operation is working smoothly.
• Make sure that the upper/lower limit sensors are installed in the correct
positions.
• Confirm that the upper/lower limit sensors come ON and go OFF
correctly during the out-lifter up/down operation.
Cylinder cycle alarm: I_CRRY
I_CRRY board transfer time up
[Cause]: • The in-carrier was advanced forward but the advance limit sensor did
not come ON within the designated amount of time.
• The in-carrier was retracted but the retract limit sensor did not come ON
within the designated amount of time.
• The in-carrier advance/retract limit sensors were both ON.
[Remedy]: • Confirm that the in-carrier advance/retract operation is working
smoothly.
• Make sure that the advance/retract limit sensors are installed in the
correct positions.
• Confirm that the advance/retract limit sensors come ON and go OFF
correctly during the in-carrier advance/retract operation.
Cylinder cycle alarm: O_CRRY
O_CRRY board transfer time up
[Cause]: • The out-carrier was advanced forward but the advance limit sensor did
not come ON within the designated amount of time.
• The out-carrier was retracted but the retract limit sensor did not come
ON within the designated amount of time.
• The out-carrier advance/retract limit sensors were both ON.
[Remedy]: • Confirm that the out-carrier advance/retract operation is working
smoothly.
• Make sure that the advance/retract limit sensors are installed in the
correct positions.
• Confirm that the advance/retract limit sensors come ON and go OFF
correctly during the out-carrier advance/retract operation.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-14 CP643E System Reference

Interlock alarm: I_CRRY
Remove board from I_LIFT
[Cause]: • With a board on the in-lifter, an attempt was made to advance the in-
carrier but whether a board was clamped on the in-carrier was
unknown. If a board with parts placed on the bottom side was clamped
on the in-carrier, the in-carrier could not be advanced since there would
be interference between the board on the in-lifter and the board clamped
on the in-carrier.
• With a board on the in-lifter and a board clamped to the in-carrier at the
advance limit, an attempt was made to retract the in-carrier. If a board
with parts placed on the bottom side was clamped on the in-carrier, the
in-carrier could not be retracted since there would be interference
between the board on the in-lifter and the board clamped on the in-
carrier.
• With a board on the in-lifter an attempt was made to retract the in-
carrier from a position that was neither the advance limit nor the retract
limit but whether a board was clamped on the in-carrier was unknown.
If a board with parts placed on the bottom side was clamped on the in-
carrier, the in-carrier could not be retracted since there would be
interference between the board on the in-lifter and the board clamped
on the in-carrier.
[Remedy]: • Remove the board on the in-lifter.
• Check the board arrival check sensor on the in-lifter to determine
whether it is detecting only the presence of a board on the in-lifter.
Interlock alarm: O_CRRY
Remove board from O_LIFT
[Cause]: • With a board on the out-lifter, an attempt was made to advance the out-
carrier but whether a board was clamped on the out-carrier was
unknown. If a board with parts placed on the bottom side was clamped
on the out-carrier, the out-carrier could not be advanced since there
would be interference between the board on the out-lifter and the board
clamped on the out-carrier.
• With a board on the out-lifter and a board clamped to the out-carrier at
the advance limit, an attempt was made to retract the out-carrier.
If a board with parts placed on the bottom side was clamped on the out-
carrier, the out-carrier could not be retracted since there would be
interference between the board on the out-lifter and the board clamped
on the out-carrier.
• With a board on the out-lifter an attempt was made to retract the out-
carrier from a position that was neither the advance limit nor the retract
limit but whether a board was clamped on the out-carrier was
unknown. If a board with parts placed on the bottom side was clamped
on the out-carrier, the out-carrier could not be retracted since there
would be interference between the board on the out-lifter and the board
clamped on the out-carrier.
[Remedy]: • Remove the board on the out-lifter.
• Check the board arrival check sensor on the out-lifter to determine
whether it is detecting only the presence of a board on the out-lifter.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-15 CP643E System Reference

PCB in loader
Remove PCB from loader
[Cause]: Operation cannot continue because there is a board in the loader (in-
conveyor, in-carrier, out-carrier, out-conveyor).
[Remedy]: Remove the board that is in the loader.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-16 CP643E System Reference