CP643 系统参考.pdf - 第276页
1. Proper Data Listing A list of the Proper data items that are used by the CP-643E is provided in the table below. The symbols listed before each of the Proper data items have the following meanings. ✩ : Varies from mac…

Part 4 Proper Data

1. Proper Data Listing
A list of the Proper data items that are used by the CP-643E is provided in the table below.
The symbols listed before each of the Proper data items have the following meanings.
✩ : Varies from machine to machine. Must be measured.
* : Cannot be changed by the user.
# : Can be changed by the user.
@ : Machine automatically changes this. (Sometimes the user can also change this).
$ : Not currently in use.
DATA NAME INPUT RANGE
# 1: ID_Code ASCII CODE = ~
# 2: Language = [English] Japanese French
# 3: Red_Light = 0000 0100 0000 0000
# 4: Yellow_Light = 0000 0000 0010 0100
# 5: Blue_Light = 0000 0011 0000 0000
# 6: Red_Flash = 0000 0000 0000 1000
# 7: Yellow_Flash = 0010 0000 0001 0010
# 8: Blue_Flash = 0000 1000 1100 0001
$# 9: User_Define A = 0000 0000 0000 0000
* 11: Machine_Status A = 0000 0000 0000 0000
# 12: Machine_Status B = 0000 0000 0000 0000
* 13: Machine_ID = 0000 0000 0000 0000
# 14: PCB_Location = [Corner] Pin
$ 20: Loader Status A = 0000 0000 0000 0000
$ 21: Loader Status B = 0000 0000 0000 0000
* 22: Conveyor Type = [L->R] R->L
$ 23: Wait Signal = [Off] On
# 24: Busy Invalid = [No] Yes
# 25: Conveyor Control = [Manu] Auto
# 26: Conveyor Adj. Limit (0.05~1.00) [mm] = 0.50
# 27: Conveyor Stop Offset (0.00~2.00) [mm] = 0.30
# 28: Conveyor adj. Timer (0~120000) [msec] = 60000
* 29: Width Max Limit (0.00~655.35) [mm] = 460.00
* 30: Width Min Limit (0.00~655.35) [mm] = 50.00
# 40: LMS Flag = [Off] On
# 41: Cell Status = [Unit] Active Passive
# 42: Change Over Mode (0~200) = 000
$# 43: Auto Start = [No] Yes
# 44: Backup Plate Check = [No] Yes
* 45: Command Line Status = [RS232C] LAN ETHERNET
# 46: Command Line Port (0~30) = 00
* 47: ID Station Type = [S_type] A_type
# 48: Buzzer Warning = [On] Off
# 49: Process Timer (1~120000) [msec] = 10000
# 50: Reader Type (0~9) = 0
# 51: Code Reader Timer (1~120000) [msec] = 10000
# 52: Code Reader Retry (0~10) = 00
# 53: Reader1 Port No. (0~30) = 00
# 54: Reader2 Port No. (0~30) = 00
# 55: PCB Code Terminal = [Non] Use
Part 4 Chapter 1 Proper Data Listing
Edition 1.0 4-1-1 CP643E System Reference

DATA NAME INPUT RANGE
$ 56: Terminal Type = [CRX1200] VT-100
# 57: Code Terminal Port (0~30) = 00
# 70: Device Check SW = No [Parts] Miss Error
# 71: Verifier Tool =[Non] Barcode Handy_term
# 72: Barcode Reader Type (0~9) = 0
# 73: Device Check Port (0~30) = 00
# 74: ESC Permission = Non [Permit]
# 75: MAN Permission = Non [Permit]
# 76: HT Comment Term. Code ASCII CODE = %
# 77: HT Verify Term. Code ASCII CODE = /
# 78: D Change Trigger = [Error] Parts Miss PD
# 80: HT Check Character = [No] Yes
✩* 100: FQ Origin Position (-30000~30000) [pulse] = 00000
✩* 101: FRQ Origin Position (-30000~30000) [pulse] = 00000
✩* 102: NC Origin Position (-30000~30000) [pulse] = 00000
✩* 103: Pickup Position T1 (-500000~0) [pulse] = 000000
✩* 104: Pickup Position T2 (0~500000) [pulse] = 000000
✩* 105: Origin Position Z (-65000~65000) [pulse] = 00000
✩* 106: Placing Position X (-100000~0) [pulse] = 000000
✩* 107: Placing Position Y (0~100000) [pulse] = 000000
✩* 108: Loading Position X IN (-100000~0) [pulse] = 000000
✩* 109: Loading Position X OUT (-100000~0) [pulse] = 000000
✩* 110: Loading Position Y IN (-100000~0) [pulse] = 00000
✩* 111: Loading Position Y OUT (-100000~0) [pulse] = 00000
✩* 112: Middle Loading Position (-65000~65000) [pulse] = 00000
✩* 113: Mark Read Position X (-100000~100000) [pulse] = 000000
✩* 114: Mark Read Position Y (0~100000) [pulse] = 000000
✩* 115: PCB Check Position X (-100000~100000) [pulse] = -27200
✩* 116: PCB Check Position Y (0~100000) [pulse] = 37900
✩* 117: D1 Origin Position (-10000~10000) [pulse] = 00000
✩* 118: D2 Origin Position (-10000~10000) [pulse] = 00000
✩* 119: Max Limit Position X (0~100000) [pulse] = 000000
✩* 120: Max Limit Position Y (0~100000) [pulse] = 000000
✩* 121: Max Limit Position D1 (0~100000) [pulse] = 000000
✩* 122: Max Limit Position D2 (-10000~500000) [pulse] = 000000
✩* 123: Max Limit Position Z (-65000~65000) [pulse] = 00000
✩* 124: Min Limit Position X (-100000~0) [pulse] = 000000
✩* 125: Min Limit Position Y (-100000~0) [pulse] = 000000
✩* 126: Min Limit Position D1 (-500000~10000) [pulse] = 000000
✩* 127: Min Limit Position D2 (-50000~50000) [pulse] = 00000
✩* 128: Min Limit Position Z (-65000~65000) [pulse] = 00000
✩* 129: Loading Position Z OUT (-65000~65000) [pulse] = 00000
✩* 130: Loading Position Z IN (-65000~65000) [pulse] = 00000
$ 131: Spare data (-1000~1000) = 00000
$ 132: Spare data (-1000~1000) = 00000
$ 133: Spare data (-1000~1000) = 00000
$ 134: Spare data (-1000~1000) = 00000
Part 4 Chapter 1 Proper Data Listing
Edition 1.0 4-1-2 CP643E System Reference