CP643 系统参考.pdf - 第255页
PICKUP T2 533-1-2 Command Pass: [SET] - [PROPER] - [D1/D2] - [Pickup Pos.] - [PICKUP T2] Press to set the pickup position T2 measurement results into Proper data. Revision History V1.10 and later ORIGIN 533-2-0 Command P…

Pickup Pos. 533-1-0
Command Pass: [SET] - [PROPER] - [D1/D2] - [Pickup Pos.]
Press to set the standard parts pickup position in Proper data.
Revision History
V1.10 and later
PICKUP T1 533-1-1
Command Pass: [SET] - [PROPER] - [D1/D2] - [Pickup Pos.] - [PICKUP T1]
Press to set the pickup position T1 measurement results into Proper data.
Revision History
V1.10 and later
SET 533-1/2/3/4-1
Command Pass: [SET] - [PROPER] - [D1/D2] - [Pickup Pos.]/[ORIGIN]/[Max Limit]
/[Min Limit] - [SET]
Press to set the relevant Proper data.
Second Display Area
The message “Set Proper” will flash in green.
First Status Area
PICKUP T1, PICKUP T2, D1 ORIGIN, D2 ORIGIN, Z0, D1 max, D2 max, Z max, D1 min, D2 min, Z
min display here depending on what Proper data is being set.
Revision History
V1.10 and later
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-94 CP643E System Reference

PICKUP T2 533-1-2
Command Pass: [SET] - [PROPER] - [D1/D2] - [Pickup Pos.] - [PICKUP T2]
Press to set the pickup position T2 measurement results into Proper data.
Revision History
V1.10 and later
ORIGIN 533-2-0
Command Pass: [SET] - [PROPER] - [D1/D2] - [ORIGIN]
Press to set the D axes Resupply position in Proper data.
Revision History
V1.10 and later
D1 ORIGIN 533-2-1
Command Pass: [SET] - [PROPER] - [D1/D2] - [ORIGIN] - [D1 ORIGIN]
Press to set the D1 origin measurement results in Proper data.
Revision History
V1.10 and later
D2 ORIGIN 533-2-2
Command Pass: [SET] - [PROPER] - [D1/D2] - [ORIGIN] - [D2 ORIGIN]
Press to set the D2 origin measurement results in Proper data.
Revision History
V1.10 and later
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-95 CP643E System Reference

Max Limit 533-3-0
Command Pass: [SET] - [PROPER] - [D1/D2] - [Max Limit]
Press to set the D positive stroke in Proper data.
Revision History
V1.10 and later
D1 Max 533-3-1
Command Pass: [SET] - [PROPER] - [D1/D2] - [Max Limit] - [D1 Max]
Press to set the D1 max measurement results in Proper data.
Revision History
V1.10 and later
D2 Max 533-3-2
Command Pass: [SET] - [PROPER] - [D1/D2] - [Max Limit] - [D2 Max]
Press to set the D2 max measurement results in Proper data.
Revision History
V1.10 and later
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-96 CP643E System Reference