CP643 系统参考.pdf - 第233页
▼ 523-1-1-1-2 Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [BEND LIMIT] - [ ▼ ] Press to move the cursor down one line. Once the cursor has reached the bottom, if pressed again it will move to the…

TOLERANCE 523-1-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE]
Press to set the nozzle bend tolerance and the nozzle back light brightness reference.
Revision History
BEND LIMIT 523-1-1-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [BEND LIMIT]
Set the nozzle bend tolerance.
Normally, if a small tolerance is input for a nozzle which is picking a small part, the check is quite
severe.
Enter bend tolerance values in units of 1/1000 mm using the numerical keypad.
[Example] If you want to enter a value of 0.3 mm, then enter 300 using the keypad and press the CR
key.
Note: If 0 is entered the tolerance will refer to the default value of 200 (0.2 mm).
Revision History
▲ 523-1-1-1-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [BEND LIMIT] - [▲]
Press to move the cursor up one line. Once the cursor has reached the top, if pressed again it will
move to the very bottom.
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-72 CP643E System Reference

▼ 523-1-1-1-2
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [BEND LIMIT] - [▼]
Press to move the cursor down one line. Once the cursor has reached the bottom, if pressed again it
will move to the very top.
Revision History
B_LITE STNDRD 523-1-1-3
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [B_LITE STNDRD]
Set the nozzle back light reference value.
Revision History
WIDE 523-1-1-3-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [B_LITE STNDRD]
- [WIDE]
Set the reference and tolerance values for the wide view camera.
Revision History
NARROW 523-1-1-3-2
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [TOLERANCE] - [B_LITE STNDRD]
- [NARROW]
Set the reference and tolerance values for the narrow view camera.
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-73 CP643E System Reference

▼ 523-1-1-3-1/2-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [NZL TOL.] - [B_LITE STNDRD]
- [WIDE]/[NARROW] - [▼]
Select between standard value input and tolerance range input.
Values for the standard value and the tolerance range can be input using the numerical keypad.
Revision History
WIDE 523-1-2
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [WIDE]
Press to display the wide camera measurement results.
Revision History
NARROW 523-1-3
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [NARROW]
Press to display the narrow view measurement results.
Revision History
Part 3 Chapter 3 Command Descriptions