CP643 系统参考.pdf - 第327页

Notes: Part 4 Chapter 2 Details of Proper Data Edition 1.1 4-2-28 CP643E System Reference

100%1 / 388
1025: Narrow Camera Center A6 Y 0 ~ 30000000 *
1044: Narrow Camera Center T6 Y 0 ~ 30000000 *
These items represent the Y-coordinates for the center of rotation of the No.6 nozzles on
head A through T respectively when nozzle center measurement is carried out on the
narrow view parts camera. The value that displays here must be divided by a factor of
65536 to obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-27 CP643E System Reference
Notes:
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-28 CP643E System Reference
Part 5
Messages