CP643 系统参考.pdf - 第307页
56: Terminal Type CRX1200: VT-100 $ Not currently in use. Default: "CRX1200” 57: Code Terminal Port 0 ~ 30 # When a Handy Terminal is used to re-read a barcode, this sets the 6-channel port number for the code reade…

47: ID Station Type S_type: A_type *
On HELPS compatible machines, this sets the location of the ID station.
S_type: The ID station is in the machine.
A_type: The ID station is outside the machine.
Default: "S_type”
48: Buzzer Warning On: Off #
On HELPS compatible machines, this sets whether or not a buzzer sounds during
changeover operator prompts.
On: Buzzer will sound.
Off: Buzzer will not sound.
Default: "On”
49: Process Timer 1 ~ 120000 [msec] #
On HELPS compatible machines, this sets the protocol timer value.
Default: 10000 msec
50: Reader Type 0 ~ 9 #
On HELPS compatible machines, when using a bar code reader, this sets the type of code
reader.
0: Bar code reader
1: Pattern code reader
Other: Bar code reader
Default: 0
51: Code Reader Timer 1 ~ 120000 [msec] #
This sets the amount of time allowed for a bar code reader to read a board type code.
Default: 10000 [msec]
52: Code Reader Retry 0 ~ 10 #
This sets the number of times a code reader will reread a board in case of a misreading the
first time.
Default: 0
53: Reader1 Port No. 0 ~ 30 #
Sets the 6-channel port number for code reader 1 (top surface).
0: Top surface code reader is not used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
54: Reader 2 Port No. 0 ~ 30 #
Sets the 6-channel port number for code reader 2 (bottom surface).
0: Bottom surface code reader is not used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
55: PCB Code Terminal Non: Use #
This sets whether or not a Handy Terminal is used for recovery.
Non: Not Used
Use: Used
Default: "Non"
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-7 CP643E System Reference

56: Terminal Type CRX1200: VT-100 $
Not currently in use.
Default: "CRX1200”
57: Code Terminal Port 0 ~ 30 #
When a Handy Terminal is used to re-read a barcode, this sets the 6-channel port number
for the code reader.
0: Handy Terminal is not used for re-reading.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
70: Device Check SW No: Parts: Miss: Error #
This sets whether or not a compulsory device check will be performed after running out of
parts, or after a program has been changed.
No: No mandatory device check
Parts: Perform mandatory device check when parts run out.
Miss: Perform mandatory device check when parts run out or when parts are mispicked.
Error: Perform mandatory device check when parts run out, parts are mispicked or when
a vision processing error occurs.
Default: "Parts"
71: Verifier Tool Non: Barcode: Handy_term #
This sets the hardware used for device check.
Non: Handy Terminal not used
Barcode: Do not use this setting
Handy_term: Handy Terminal used
If “Barcode” is used, the device check may not work.
Default: "Non"
72: Barcode Reader Type 0 ~ 9 #
This sets the type of bar code reader used in device check.
0: Not used
Ensure this is set to “5” (HC-70-FK) if this Proper data item is used.
Default: 0
73: Device Check Port 0 ~ 30 #
If a Handy Terminal is used during device check, this sets the 6-channel port number.
0: Handy Terminal not used
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
74: ESC Permission Non: Permit #
This sets whether or not the [ESC] command can be used during device check.
Non: [ESC] command cannot be used
Permit: [ESC] command can be used
Default: "Permit”
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-8 CP643E System Reference

75: MAN Permission Non: Permit #
This sets whether or not data can be input from the keypad on the Handy Terminal.
Non: Keypad cannot be used
Permit: Keypad can be used
Default: "Permit”
76: HT Comment Term. Code ASCII CODE #
The Handy Terminal will disregard the comments embedded in the selected ASCII code.
Default: "%”
77: HT Verify Term. Code ASCII CODE #
The Handy Terminal will disregard any comments thereafter.
Default: “/”
78: D Change Trigger Error: Parts: Miss PD #
This sets the conditions under which device change (to the next device) is carried out.
Error: Carried out if parts run out, if parts are mispicked or if there is a vision processing
error.
Parts: Carried out if parts run out.
Miss: Carried out if parts run out or if parts are mispicked.
PD: Carried out according to the conditions laid out in Part data.
Default: "Error”
80: HT. Check Character #
This is used to enable the check character for the Handy Terminal.
No: Check character is not used.
Yes: Check character is used.
Default: “No”
100: FQ Origin Position -30000 ~ 30000 [pulse] ✩*
This is the position of the FQ-axis after the zero set procedure is completed.
As for the value of this Proper data item, the standard position is the position where the
station 10 nozzle shaft engages the clutch. This item should be treated with extreme
caution. If this value is changed station 10 rotation may not be possible and in the worst
case scenario it can lead to damage to the machine.
It is necessary to remeasure this value when the motor has been changed. On the FQ-axis, 1
pulse is 0.05 degrees.
Default is the Proper data calibration result.
101: FRQ Origin Position -30000 ~ 30000 [pulse] ✩*
This is the position of the FRQ-axis after the zero set procedure is completed.
As for the value of this Proper data item, the standard position is the position where the
station 12 nozzle shaft engages the clutch. This item should be treated with extreme
caution. If this value is changed station 12 rotation may not be possible and in the worst
case scenario it can lead to damage to the machine.
It is necessary to remeasure this value when the motor has been changed. On the FRQ-axis,
1 pulse is 0.05 degrees.
Default is the Proper data calibration result.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-9 CP643E System Reference