CP643 系统参考.pdf - 第319页
406: Device Offset 1 -32.768 ~ 32.767 [mm] # ⇓ 545: Device Offset 140 -32.768 ~ 32.767 [mm] # This sets the amount of device offset for picking parts. Input is entered in millimeters. If a vision processing error is gene…

266: A6 Place Offset X -327.68 ~ 327.67 [mm] ✩*
⇓
285: T6 Place Offset X -327.68 ~ 327.67 [mm] ✩*
This sets the amount of X direction offset for the No.3 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
286: A1 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
⇓
305: T1 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
This sets the amount of Y direction offset for the No.1 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
306: A2 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
⇓
325: T2 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
This sets the amount of Y direction offset for the No.2 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
326: A3 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
⇓
345: T3 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
This sets the amount of Y direction offset for the No.3 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
346: A4 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
⇓
365: T4 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
This sets the amount of Y direction offset for the No.4 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
366: A5 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
⇓
385: T5 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
This sets the amount of Y direction offset for the No.5 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
386: A6 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
⇓
405: T6 Place Offset Y -327.68 ~ 327.67 [mm] ✩*
This sets the amount of Y direction offset for the No.6 nozzle position at station 11.
If this value is changed the machine will not place parts accurately.
Default is the Proper data calibration result.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-19 CP643E System Reference

406: Device Offset 1 -32.768 ~ 32.767 [mm] #
⇓
545: Device Offset 140 -32.768 ~ 32.767 [mm] #
This sets the amount of device offset for picking parts. Input is entered in millimeters. If a
vision processing error is generated due to part displacement (left or right) caused by the
condition of the feeder or the tape, this offset value can be changed to allow the part to be
picked closer to the center of the part. The value input normally offsets only the device for
which it has been input. It is also possible to edit this value on the machine.
Default: 0
548: Back light stn. Value Wide 0 ~ 255
The standard value from background disk lumination level measurement carried out during
nozzle center measurement is stored in this data item.
Default : 170
549: Back light stn. Value Narrow 0 ~ 255
The standard value from background disk lumination level measurement carried out during
nozzle center measurement is stored in this data item.
Default : 150
550: Mark Camera Pixel X 0 ~ 5000000 ✩*
This sets the size of 1 pixel in the X direction for the mark camera. The value that displays
here must be divided by a factor of 65536 to obtain a value expressed in mm units. The user
cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
551: Mark Camera Pixel Y 0 ~ 4000000 ✩*
This sets the size of 1 pixel in the Y direction for the mark camera. The value that displays
here must be divided by a factor of 65536 to obtain a value expressed in mm units. The user
cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
552: Mark Camera Rotation -196608000 ~ 196608000 ✩*
This sets the orientation of the mark camera. The value that displays here must be divided
by a factor of 65536 to obtain a value expressed in units of 0.001°. The user cannot change
this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
553: Mark Camera Gain 0 ~ 255 ✩*
This sets the gain level for the mark camera. It should not be necessary for the user to
change this setting.
The gain level that has been set for the mark camera must be transmitted from the machine
to the host computer.
554: Mark Camera Offset 0 ~ 255 ✩*
This sets the offset level for the mark camera. It should not be necessary for the user to
change this setting.
The offset level that has been set for the mark camera must be transmitted from the machine
to the host computer.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-20 CP643E System Reference

555: Wide Camera Pixel X 0 ~ 6000000 ✩*
This sets the size of 1 pixel in the X direction for the wide view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value expressed in mm units.
The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
556: Wide Camera Pixel Y 0 ~ 6000000 ✩*
This sets the size of 1 pixel in the Y direction for the wide view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value expressed in mm units.
The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
557: Wide Camera Rotation -196608000 ~ 196608000 ✩*
This sets the orientation of the wide view parts camera. The value that displays here must
be divided by a factor of 65536 to obtain a value expressed in units of 0.001°. The user
cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
558: Wide Camera Gain 0 ~ 255 ✩*
This sets the gain level for the wide view parts camera. It should not be necessary for the
user to change this setting.
The gain level that has been set for the wide view camera must be transmitted from the
machine to the host computer.
559: Wide Camera Offset 0 ~ 255 ✩*
This sets the offset level for the wide view parts camera. It should not be necessary for the
user to change this setting.
The offset level that has been set for the wide view camera must be transmitted from the
machine to the host computer.
560: Narrow Camera Pixel X 0 ~ 5000000 ✩*
This sets the size of 1 pixel in the X direction for the narrow view parts camera. The value
that displays here must be divided by a factor of 65536 to obtain a value expressed in mm
units. The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
561: Narrow Camera Pixel Y 0 ~ 5000000 ✩*
This sets the size of 1 pixel in the Y direction for the narrow view parts camera. The value
that displays here must be divided by a factor of 65536 to obtain a value expressed in mm
units. The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-21 CP643E System Reference