NOZZLE DA T A 523-1-5-1/2-1 Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY] - [WIDE]/[NARROW] - [NOZZLE DATA] Display nozzle bend results. Revision History +P AGE 523-1-5-1/2-1-1 Command Pass: [SET] - [M…

DISPLAY DATA 523-1-5
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY DATA ]
This command is used to display the nozzle bend and background disk measurement data.
Each part of the display has the following meanings.
Nozzle bend tolerance
Either the nozzle bend tolerance specified in the program or the tolerance value set using the
[TOLERANCE] command is displayed.
Nozzle check results
A nozzle with an error (center measurement error, nozzle bend error, or nozzle size error: nozzle
that is not within +/- 15% of the specified nozzle size) will display as “NG” (red).
Measured nozzle bend
The distance between the measured center of rotation position and the nozzle tip position is
displayed.
Green: The above noted distance is within the nozzle bend tolerance
Red: The above noted distance exceeds the specified nozzle bend tolerance.
Revision History
WIDE / NARROW 523-1-5-1/2
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW]
Press to display the measurements acquired by the wide view camera/narrow view camera.
Revision History
CP643S3022
BENT NOZZLE [mm] AND NOZZLE DIAMETER CHECK
NOZZLE 1
HEAD A
HEAD B
HEAD C
HEAD D
HEAD E
HEAD F
HEAD G
HEAD H
HEAD I
HEAD J
NOZZLE 2 NOZZLE 3 LIMIT
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
NG
NG
NG
NG
NG
NG
NG
NG
NG
NG
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
0.000
1
2
3
4
5
6
Nozzle bend tolerance
Nozzle check results
NG (Red): Unusable nozzle
Nozzle bend measurement
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-76 CP643E System Reference

NOZZLE DATA 523-1-5-1/2-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW] - [NOZZLE DATA]
Display nozzle bend results.
Revision History
+PAGE 523-1-5-1/2-1-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW] - [NOZZLE DATA] - [+PAGE]
Press to change the display from heads A~J to heads K~T.
Revision History
-PAGE 523-1-5-1/2-1-2
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW] - [NOZZLE DATA] - [-PAGE]
Press to change the display from heads A~J to heads K~T.
Revision History
NOZZLE TYPE 523-1-5-1/2-1-3
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW] - [NOZZLE DATA] - [NOZZLE TYPE]
This is used to change between nozzle No.1~3 and nozzle No. 4 ~ 6.
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-77 CP643E System Reference

BACKLIGHT DATA 523-1-5-1/2-2
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW] - [BACKLIGHT DATA]
Display nozzle back light measurement results.
Caution: The data displayed on the screen is the nozzle type data selected using the command. The
nozzle type display also changes accordingly.
When this screen is first opened (default), the No. 1 nozzle data is displayed.
The camera type selected using the higher order command will display in yellow.
In each data display, the value will display in white if it is within the tolerance range and in red if
it is not within the tolerance. In addition, for nozzles with a measurement error instead of a
value being displayed, “∗∗∗” will display in yellow.
Revision History
PAGE 523-1-5-1/2-2-1
Command Pass: [SET] - [MANUAL] - [NOZZLE] - [CENTER] - [DISPLAY]
- [WIDE]/[NARROW] - [BACKLIGHT DATA] - [PAGE]
The display toggles between the measurement results for nozzle heads A ~ J and K ~ T.
Revision History
CP643S3023
BACK LIGHT CONDITION
NOZZLE: 1
CAMERA: WIDE VIEW
Head
A
B
C
D
E
Gray
176
***
193
201
169
Dev
16
***
25
16
23
STANDARD VALUE
STANDARD DEV
Head
F
G
H
I
J
Gray
***
183
189
191
179
Dev
***
27
18
20
19
: 170 (± 20)
: 0 (+ 3)
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-78 CP643E System Reference