CP643 系统参考.pdf - 第306页

47: ID Station Type S_type: A_type * On HELPS compatible machines, this sets the location of the ID station. S_type: The ID station is in the machine. A_type: The ID station is outside the machine. Default: "S_type”…

100%1 / 388
29: Width Max Limit 0.00 ~ 655.35 [mm] *
This sets the maximum conveyor width value.
Default: 460.00 mm
30: Width Min Limit 0.00 ~ 655.35 [mm] *
This sets the minimum conveyor width value.
Default: 50.00 mm
40: LMS Flag Off: On #
This sets whether the unit will be a HELPS compatible machine or not.
Off: Not compatible
On: Compatible
Default: "Off"
41: Cell Status Unit: Active: Passive #
This is only valid for HELPS compatible machines. This sets the cell status.
Unit: Unit cell
Active: Active cell
Passive: Passive cell
Default: "Unit"
42: Change Over Mode 0 ~ 200 #
This is valid only for HELPS compatible machines. It sets the method of reporting the board
type.
Default: 0
43: Auto Start No: Yes $#
This is valid only for HELPS compatible machines. It sets the start-up method after
changeover has been completed.
No: Machine waits for START button to be pressed after changeover has finished.
Yes: Automatic start
Default: "No” ‘Automatic start’ is not currently supported.
44: Backup Plate Check No: Yes #
On HELPS compatible machines, this determines whether a backup plate check will be done
during changeover.
No: No backup plate changeover check.
Yes: Backup plate changeover check.
Default: "No"
45: Command Line Status RS232C: LAN: ETHERNET *
Default: “RS232C” (“LAN” and “ETHERNET” are not currently supported).
46: Command Line Port 0 ~ 30 #
Specify the port number on the 6-channel communications board when a RS232C cable is
being used.
0: Command line will not be used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-6 CP643E System Reference
47: ID Station Type S_type: A_type *
On HELPS compatible machines, this sets the location of the ID station.
S_type: The ID station is in the machine.
A_type: The ID station is outside the machine.
Default: "S_type”
48: Buzzer Warning On: Off #
On HELPS compatible machines, this sets whether or not a buzzer sounds during
changeover operator prompts.
On: Buzzer will sound.
Off: Buzzer will not sound.
Default: "On”
49: Process Timer 1 ~ 120000 [msec] #
On HELPS compatible machines, this sets the protocol timer value.
Default: 10000 msec
50: Reader Type 0 ~ 9 #
On HELPS compatible machines, when using a bar code reader, this sets the type of code
reader.
0: Bar code reader
1: Pattern code reader
Other: Bar code reader
Default: 0
51: Code Reader Timer 1 ~ 120000 [msec] #
This sets the amount of time allowed for a bar code reader to read a board type code.
Default: 10000 [msec]
52: Code Reader Retry 0 ~ 10 #
This sets the number of times a code reader will reread a board in case of a misreading the
first time.
Default: 0
53: Reader1 Port No. 0 ~ 30 #
Sets the 6-channel port number for code reader 1 (top surface).
0: Top surface code reader is not used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
54: Reader 2 Port No. 0 ~ 30 #
Sets the 6-channel port number for code reader 2 (bottom surface).
0: Bottom surface code reader is not used.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
55: PCB Code Terminal Non: Use #
This sets whether or not a Handy Terminal is used for recovery.
Non: Not Used
Use: Used
Default: "Non"
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-7 CP643E System Reference
56: Terminal Type CRX1200: VT-100 $
Not currently in use.
Default: "CRX1200”
57: Code Terminal Port 0 ~ 30 #
When a Handy Terminal is used to re-read a barcode, this sets the 6-channel port number
for the code reader.
0: Handy Terminal is not used for re-reading.
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
70: Device Check SW No: Parts: Miss: Error #
This sets whether or not a compulsory device check will be performed after running out of
parts, or after a program has been changed.
No: No mandatory device check
Parts: Perform mandatory device check when parts run out.
Miss: Perform mandatory device check when parts run out or when parts are mispicked.
Error: Perform mandatory device check when parts run out, parts are mispicked or when
a vision processing error occurs.
Default: "Parts"
71: Verifier Tool Non: Barcode: Handy_term #
This sets the hardware used for device check.
Non: Handy Terminal not used
Barcode: Do not use this setting
Handy_term: Handy Terminal used
If “Barcode” is used, the device check may not work.
Default: "Non"
72: Barcode Reader Type 0 ~ 9 #
This sets the type of bar code reader used in device check.
0: Not used
Ensure this is set to “5” (HC-70-FK) if this Proper data item is used.
Default: 0
73: Device Check Port 0 ~ 30 #
If a Handy Terminal is used during device check, this sets the 6-channel port number.
0: Handy Terminal not used
1 - 10: Do not specify 1 to 10.
11 - 30: Port numbers. On a 6-channel board the valid settings are 11 to 16.
Default: 0
74: ESC Permission Non: Permit #
This sets whether or not the [ESC] command can be used during device check.
Non: [ESC] command cannot be used
Permit: [ESC] command can be used
Default: "Permit”
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-8 CP643E System Reference