CP643 系统参考.pdf - 第188页

Print 354-5-1 Command Pass: [LOADER] - [Loader Pos] - [CYL ADJ] - [Data Save] - [Print] Ready : The measurement results are output to the printer. Revision History V1.11 and later Down Load 354-5-3 Command Pass: [LOADER]…

100%1 / 388
TIMES 354-2-0
Command Pass: [LOADER] - [Loader Pos] - [CYL ADJ] - [TIMES]
Input the number of measurement times using the numeric keypad.
Valid input values are from 0 to 100. If “0” is input the measurement operation will continue until
either CYCLE STOP is pressed or an error occurs causing the machine to stop. The setting that has
been input will display under Movements in the first display area.
Revision History
V1.11 and later
START 354-4-0
Command Pass: [LOADER] - [Loader Pos] - [CYL ADJ] - [START]
The START button and F6 [RETURN] are enabled.
The measurement operation commences if the START button is pressed.
The START button is disabled if [RETURN] is pressed.
The measurement item displays when it is selected.
Revision History
V1.11 and later
Data Save 354-5-0
Command Pass: [LOADER] - [Loader Pos] - [CYL ADJ] - [Data Save]
The measurement results are either printed out or downloaded as a file.
Revision History
V1.11 and later
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-27 CP643E System Reference
Print 354-5-1
Command Pass: [LOADER] - [Loader Pos] - [CYL ADJ] - [Data Save] - [Print]
Ready : The measurement results are output to the printer.
Revision History
V1.11 and later
Down Load 354-5-3
Command Pass: [LOADER] - [Loader Pos] - [CYL ADJ] - [Data Save] - [Down Load]
Ready : The measurement results are transmitted to the personal computer.
Trans Port : Use the numeric keypad to specify the port number used when transmitting the
results to the personal computer.
The valid input values are “3” and “4” when communication with the host is carried out using
RS232C. When communication with the host is carried out using internal C/C or internal C/C +
SECS/GEM, the valid input values are “2 ~ 4”.
Note however that in any of these cases the default port number is “4”.
Revision History
V1.11 and later
PROGRAM 400-0-0
Command Pass: [PROGRAM]
Press to select a production program.
The names of all programs (1~9) currently stored in the machine are displayed.
Program Name : Program name
Prod. : Completed production quantity
Sche. : Scheduled production quantity
If a program name displays in yellow, it has been specified as the next production program.
Programs which caused an error during partial transmission or the data check, display in red. It is
possible to bring such programs to the foreground, but it is not possible to commence production
([STEP] and [AUTO] are not available).
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-28 CP643E System Reference
CHANGE 410-0-0
Command Pass: [PROGRAM] - [CHANGE]
Press to change the production program.
Input program number using numerical keypad.
• Changeover will take place if an input program number has been existed.
• When changeover takes place the data necessary for placing parts will be processed and the
message "Calculating Placing Data" will display.
Revision History
QTY. SET 420-0-0
Command Pass: [PROGRAM] - [QTY. SET]
Press to change the scheduled production quantity.
Input from the numerical keypad the number of boards to be produced under the current
production program.
Enter a number between 1 and 65,000. When the number of boards produced reaches the scheduled
production quantity the machine quits automatic operation and the RESET button is enabled. If the
scheduled production quantity is set to “0” this will be judged as no scheduled quantity and
production will continue indefinitely.
Production will continue indefinitely if a value of 0 is entered.
The display then returns to command page 400.
Revision History
QTY. CLEAR 430-0-0
Command Pass: [PROGRAM] - [QTY. CLEAR]
Press to clear the completed production quantity to zero.
Revision History
Part 3 Chapter 3 Command Descriptions
Edition 1.0 3-3-29 CP643E System Reference