CP643 系统参考.pdf - 第46页

The color of the display has the following meanings. The relationships between the displays above are shown in the Venn diagram below. If the device check function is not used, the setting of parts can only be canceled o…

100%1 / 388
Area B: The operation modes are displayed here.
• P Mode: This item indicates whether the machine is currently in Product, Simulate, or
Idle or Idle 2 operation mode.
• Recovery: This item indicates which of the three recovery modes (E Pass, E Stop, or N
times) the machine is currently using.
• T Mode: This item indicates which of the device table modes are in operation.
When original table is designated, the sign " ** " will appear on its side.
Display
Joint
2A 1A **
2B 1A **
(2A1B)
Meaning
Joint Mode: The two tables move synchronously.
Device Change Mode: One device table is used as the spare
table for the other table.
Changeover Mode: Only one table operates and each table
operates for a separate program.
CP643S1023
Display
Times
Error Stop
Error Pass
Meaning
The number of times that recovery is repeated can be set.
Refer to Part 3, Chapter 3, "Command Descriptions" for
a more detailed explanation.
When an error occurs, the machine stops and recovery is
carried out when the machine is started again.
When an error occurs, the machine does not stop and no
recovery is carried out.
CP643S1022
Display
Product
Simulate
Idle
Idle 2
Meaning
The machine is in normal production mode.
The machine carries out a simulation of normal production.
Boards are loaded, and only the X-, Y-, D1- and D2-axes move
as they do during production for the selected production program.
The machine does not feed boards or perform vision
processing. Otherwise, it is the same as Product mode.
While in this mode there should be no parts on the device table.
In addition to the idling operation, in-/out-carrier operation and
board transfer actions between the XY-table and the carriers are
performed. (Actual board exchanges do not occur.)
When in this mode, there should be no parts on the device table.
CP643S1021
Part 1 Chapter 1 Machine Overview
Edition 1.1 1-1-19 CP643E System Reference
The color of the display has the following meanings.
The relationships between the displays above are shown in the Venn diagram below.
If the device check function is not used, the setting of parts can only be canceled or
completed using the [PARTS SET] [CANCEL/COMPLETE] switch.
Refer to “Part 2, Chapter 1, 1.7 Device Check”, for details about the device check function
and the parts set cancel/complete operation.
Table display Color
Red
Red
Blue
Yellow
Green
Purple
White
White
Production Table Reservation
Part set complete
Device check complete
CP643S1025
Display
Green
Yellow
White
Purple
Blue
Meaning
Original table with device check and the parts set
operation complete
Device check and the parts set operation complete on the
table that is not the original table
Device check completed, parts set SW is not complete
Parts set complete, device check not complete on original table
Parts set complete, device check not complete on table that is
not the original table
CP643S1024
Part 1 Chapter 1 Machine Overview
Edition 1.1 1-1-20 CP643E System Reference
Area C: Special operations procedures display here.
Area D: Information about optional functions display here.
• In the case of Handy Terminal compatible operation
When the next program has been specified, the name of this program will display
here.
• When operating in the HELPS mode
The name of the announcement or reservation program will display here.
Display
Ending one board production
Ending two board production
Unloading
Checking Device by HT
Calculating Placing Data
Vision processing
Meaning
After finishing the board currently being processed
the machine will stop.
Machine is being stopped following two board
production operation.
Machine is being stopped after all boards in the
machine (on the in-conveyor, in-carrier, main
conveyor, out-carrier, and out-conveyor) have been
completed and unloaded.
Device check is currently being carried out using a
Handy Terminal.
Calculation of data necessary for placing parts is
currently being carried out.
Waiting for vision processing to be completed.
CP643S1026
Part 1 Chapter 1 Machine Overview
Edition 1.1 1-1-21 CP643E System Reference