Board check error: O_CRRY Could not check board Adjust sensor [Cause]: • When the out-carrier received a board from the main lifter, the out- carrier board check sensor did not confirm the board (sensor ON). • After the …

100%1 / 388
PCB Setting Error: I_LIFT
Check board-gap sensor on the I_LIFT
[Cause]: • There are two boards despite the fact that the machine is in the one
board production mode.
• There are two boards despite the fact that the supply instruction was for
one board in the two board production mode.
• There is a problem with the position of a board on the in-conveyor such
that transport is not possible.
• The status of boards on the in-conveyor could not be checked.
[Remedy]: • Set the number of boards to match the board production mode.
• Set the board(s) in the correct position(s).
• Verify that the sensor for checking boards on the in-conveyor is able to
correctly detect the presence of boards on the conveyor. Note also that
the board gap check sensor should be ON when there is no board and
OFF when there is a board.
PCB Setting Error: O_LIFT
Check board-gap sensor on the O_LIFT
[Cause]: • There is a problem with the position of a board on the out-conveyor
such that transport is not possible.
• The status of boards on the out-conveyor could not be checked.
[Remedy]: • Set the board(s) in the correct position(s).
• Verify that the sensor for checking boards on the out-conveyor is able to
correctly detect the presence of boards on the conveyor. Note also that
the board gap check sensor should be ON when there is no board and
OFF when there is a board.
Board check error: I_CRRY
Could not check board
Adjust sensor
[Cause]: After the in-carrier transported a board to the advance limit and the board
was checked by the in-carrier board check sensor (No. 1 and No. 2 board
check status) but prior to the main lifter receiving the in-carrier board, the
in-carrier board check sensor went OFF so that the No. 1 or No. 2 board
check status changed (no board status).
[Remedy]: Adjust the in-carrier board check sensor so that boards clamped on the in-
carrier are accurately detected.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-12 CP643E System Reference
Board check error: O_CRRY
Could not check board
Adjust sensor
[Cause]: • When the out-carrier received a board from the main lifter, the out-
carrier board check sensor did not confirm the board (sensor ON).
• After the out-carrier received a board from the main lifter and the board
was confirmed (sensor ON) by the out-carrier board check sensor but
prior to retraction of the out-carrier, the out-carrier board check sensor
went OFF (no board status).
• After the out-carrier board check sensor confirmed a board (sensor ON)
while at the out-carrier advance limit during out-carrier board check but
prior to the start of out-carrier retraction, the out-carrier board check
sensor went OFF (no board status).
[Remedy]: Adjust the out-carrier board check sensor so that boards clamped on the
out-carrier are accurately detected. Sufficient care should be exercised if it
is determined that no board exists despite a board being on the out-carrier.
In such a case if the machine is restarted without adjusting the sensor, the
board will be released after out-carrier board check.
Board check sensor alarm: I_LIFT
Check board-check sensor on the I_LIFT
[Cause]: There is a problem with the board check sensor on the in-lifter. (For
example, the sensor is ON when it should be OFF.)
[Remedy]: Confirm that the in-lifter board check sensor comes ON and goes OFF
correctly. Also be sure that the board gap check sensor is ON when there
is no board and OFF when there is a board.
Board check sensor alarm: O_LIFT
Check board-check sensor on the O_LIFT
[Cause]: There is a problem with the board check sensor on the out-lifter. (For
example, the sensor is ON when it should be OFF.)
[Remedy]: Confirm that the out-lifter board check sensor comes ON and goes OFF
correctly. Also be sure that the board gap check sensor is ON when there
is no board and OFF when there is a board.
Board check sensor alarm: I_CRRY
Board-check sensor on the I_CRRY is ON
[Cause]: There is a problem with the board check sensor on the in-carrier. (The
sensor is ON when it should be OFF.)
[Remedy]: Confirm that the sensor for checking boards on the in-carrier comes ON
and goes OFF correctly.
Board check sensor alarm: O_CRRY
Board-check sensor on the O_CRRY is ON
[Cause]: There is a problem with the board check sensor on the out-carrier. (The
sensor is ON when it should be OFF.)
[Remedy]: Confirm that the sensor for checking boards on the out-carrier comes ON
and goes OFF correctly.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-13 CP643E System Reference
Cylinder cycle alarm: I_LIFT
Up/down movement of the I_LIFT time up
[Cause]: • The in-lifter was raised but the upper limit sensor did not come ON
within the designated amount of time.
• The in-lifter was lowered but the lower limit sensor did not come ON
within the designated amount of time.
• The in-lifter upper limit/lower limit sensors were both ON.
[Remedy]: • Confirm that the in-lifter up/down operation is working smoothly.
• Make sure that the upper/lower limit sensors are installed in the correct
positions.
• Confirm that the upper/lower limit sensors come ON and go OFF
correctly during the in-lifter up/down operation.
Cylinder cycle alarm: O_LIFT
Up/down movement of the O_LIFT time up
[Cause]: • The out-lifter was raised but the upper limit sensor did not come ON
within the designated amount of time.
• The out-lifter was lowered but the lower limit sensor did not come ON
within the designated amount of time.
• The out-lifter upper limit/lower limit sensors were both ON.
[Remedy]: • Confirm that the out-lifter up/down operation is working smoothly.
• Make sure that the upper/lower limit sensors are installed in the correct
positions.
• Confirm that the upper/lower limit sensors come ON and go OFF
correctly during the out-lifter up/down operation.
Cylinder cycle alarm: I_CRRY
I_CRRY board transfer time up
[Cause]: • The in-carrier was advanced forward but the advance limit sensor did
not come ON within the designated amount of time.
• The in-carrier was retracted but the retract limit sensor did not come ON
within the designated amount of time.
• The in-carrier advance/retract limit sensors were both ON.
[Remedy]: • Confirm that the in-carrier advance/retract operation is working
smoothly.
• Make sure that the advance/retract limit sensors are installed in the
correct positions.
• Confirm that the advance/retract limit sensors come ON and go OFF
correctly during the in-carrier advance/retract operation.
Cylinder cycle alarm: O_CRRY
O_CRRY board transfer time up
[Cause]: • The out-carrier was advanced forward but the advance limit sensor did
not come ON within the designated amount of time.
• The out-carrier was retracted but the retract limit sensor did not come
ON within the designated amount of time.
• The out-carrier advance/retract limit sensors were both ON.
[Remedy]: • Confirm that the out-carrier advance/retract operation is working
smoothly.
• Make sure that the advance/retract limit sensors are installed in the
correct positions.
• Confirm that the advance/retract limit sensors come ON and go OFF
correctly during the out-carrier advance/retract operation.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-14 CP643E System Reference