CP643 系统参考.pdf - 第321页

562: Narrow Camera Rotation -19660800 ~ 19660800 ✩ * This sets the orientation of the narrow view parts camera. The value that displays here must be divided by a factor of 65536 to obtain a value expressed in units of 0.…

100%1 / 388
555: Wide Camera Pixel X 0 ~ 6000000 *
This sets the size of 1 pixel in the X direction for the wide view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value expressed in mm units.
The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
556: Wide Camera Pixel Y 0 ~ 6000000 *
This sets the size of 1 pixel in the Y direction for the wide view parts camera. The value that
displays here must be divided by a factor of 65536 to obtain a value expressed in mm units.
The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
557: Wide Camera Rotation -196608000 ~ 196608000 *
This sets the orientation of the wide view parts camera. The value that displays here must
be divided by a factor of 65536 to obtain a value expressed in units of 0.001°. The user
cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
558: Wide Camera Gain 0 ~ 255 *
This sets the gain level for the wide view parts camera. It should not be necessary for the
user to change this setting.
The gain level that has been set for the wide view camera must be transmitted from the
machine to the host computer.
559: Wide Camera Offset 0 ~ 255 *
This sets the offset level for the wide view parts camera. It should not be necessary for the
user to change this setting.
The offset level that has been set for the wide view camera must be transmitted from the
machine to the host computer.
560: Narrow Camera Pixel X 0 ~ 5000000 *
This sets the size of 1 pixel in the X direction for the narrow view parts camera. The value
that displays here must be divided by a factor of 65536 to obtain a value expressed in mm
units. The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
561: Narrow Camera Pixel Y 0 ~ 5000000 *
This sets the size of 1 pixel in the Y direction for the narrow view parts camera. The value
that displays here must be divided by a factor of 65536 to obtain a value expressed in mm
units. The user cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-21 CP643E System Reference
562: Narrow Camera Rotation -19660800 ~ 19660800 *
This sets the orientation of the narrow view parts camera. The value that displays here must
be divided by a factor of 65536 to obtain a value expressed in units of 0.001°. The user
cannot change this setting.
Default is the Proper data measurement result, which upon measurement must be
transmitted from the machine to the host computer.
563: Narrow Camera Gain 0 ~ 255 *
This sets the gain level for the narrow view parts camera. It should not be necessary for the
user to change this setting.
The gain level that has been set for the narrow view camera must be transmitted from the
machine to the host computer.
564: Narrow Camera Offset 0 ~ 255 *
This sets the offset level for the narrow view parts camera. It should not be necessary for
the user to change this setting.
The offset level that has been set for the narrow view camera must be transmitted from the
machine to the host computer.
565: Wide Camera Center A1 X 0 ~ 30000000 *
584: Wide Camera Center T1 X 0 ~ 30000000 *
These items represent the X-coordinates for the center of rotation of the No.1 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
585: Wide Camera Center A1 Y 0 ~ 30000000 *
604: Wide Camera Center T1 Y 0 ~ 30000000 *
These items represent the Y-coordinates for the center of rotation of the No.1 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
605: Wide Camera Center A2 X 0 ~ 30000000 *
624: Wide Camera Center T2 X 0 ~ 30000000 *
These items represent the X-coordinates for the center of rotation of the No.2 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-22 CP643E System Reference
625: Wide Camera Center A2 Y 0 ~ 30000000 *
644: Wide Camera Center T2 Y 0 ~ 30000000 *
These items represent the Y-coordinates for the center of rotation of the No.2 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
645: Wide Camera Center A3 X 0 ~ 30000000 *
664: Wide Camera Center T3 X 0 ~ 30000000 *
These items represent the X-coordinates for the center of rotation of the No.3 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
665: Wide Camera Center A3 Y 0 ~ 30000000 *
684: Wide Camera Center T3 Y 0 ~ 30000000 *
These items represent the Y-coordinates for the center of rotation of the No.3 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
685: Wide Camera Center A4 X 0 ~ 30000000 *
704: Wide Camera Center T4 X 0 ~ 30000000 *
These items represent the X-coordinates for the center of rotation of the No.4 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
705: Wide Camera Center A4 Y 0 ~ 30000000 *
724: Wide Camera Center T4 Y 0 ~ 30000000 *
These items represent the Y-coordinates for the center of rotation of the No.4 nozzles on
head A through T respectively when nozzle center measurement is carried out on the wide
view parts camera. The value that displays here must be divided by a factor of 65536 to
obtain a value expressed in mm units.
These default values are based on the results of nozzle center measurement and must be
transmitted from the machine to the host computer after being measured.
Part 4 Chapter 2 Details of Proper Data
Edition 1.1 4-2-23 CP643E System Reference