CP643 系统参考.pdf - 第336页
OUT-car for/bck lmt bth ON [Cause]: The out-carrier advance limit check sensor and retract limit check sensor are both ON. [Remedy]: Check the out-carrier advance limit check sensor (LX03C) and retract limit check sensor…

Coolant Oil Circulate Prob.
[Cause]: The cooling oil pressure is not within the pressure limits.
[Remedy]: Shut off the power and check the oil level.
Nozl Origin Search Err: stn12
[Cause]: The clutch is not engaging and the nozzle clutch origin position cannot be
confirmed.
[Remedy]: The engaging sensor and/or the origin position sensor adjustment is no
good. Also the shaft automatic prevention function may not be good.
Adjust it after locating the cause.
ST15 nozzle origin error
[Cause]: The machine was not able to confirm the nozzle holder is at the origin
position with the check at station 15.
[Remedy]: Return the nozzle holder in question close to its origin position. Ensure
the nozzle holder is not set to plus or minus 90° from the origin or the
nozzles may interfere with other nozzle holders.
IN-car for/bck lmt both OFF
[Cause]: The in-carrier advance limit check sensor and retract limit check sensor are
both OFF.
[Remedy]: Check the in-carrier advance limit check sensor (LX01C) and retract limit
check sensor (LX01D). If the carrier has stopped at some point between the
limit positions then either advance or retract the carrier.
IN-car for/bck lmt both ON
[Cause]: The in-carrier advance limit check sensor and retract limit check sensor are
both ON.
[Remedy]: Check the in-carrier advance limit check sensor (LX01C) and the retract
limit check sensor (LX01D).
IN-car clp lmts both OFF extended limit
[Cause]: The in-carrier advance limit side close check sensors and the in-carrier
advance limit side open check sensors are both OFF.
[Remedy]: Check the in-carrier advance limit side close check sensors (LX042, LX043)
and the in-carrier advance limit side open check sensors (LX046, LX047). If
the carrier has stopped at some point in progress then either open or close
the in-carrier.
IN-car clp lmts both ON extended limit
[Cause]: The in-carrier advance limit side close check sensors and the in-carrier
advance limit side open check sensors are both ON.
[Remedy]: Check the in-carrier advance limit side close check sensors (LX042, LX043)
and the in-carrier advance limit side open check sensors (LX046, LX047).
OUT-car for/bck lmt bth OFF
[Cause]: The out-carrier advance limit check sensor and retract limit check sensor
are both OFF.
[Remedy]: Check the out-carrier advance limit check sensor (LX03C) and retract limit
check sensor (LX03D). If the carrier has stopped at some point between the
limit positions then either advance or retract the out-carrier.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-7 CP643E System Reference

OUT-car for/bck lmt bth ON
[Cause]: The out-carrier advance limit check sensor and retract limit check sensor
are both ON.
[Remedy]: Check the out-carrier advance limit check sensor (LX03C) and retract limit
check sensor (LX03D).
OUT-car clp lmts both OFF extended limit
[Cause]: The out-carrier advance limit side close check sensors and the out-carrier
advance limit side open check sensors are both OFF.
[Remedy]: Check the out-carrier advance limit side close check sensors (LX048,
LX049) and the out-carrier advance limit side open check sensors (LX04C,
LX04D). If the carrier has stopped at some point in progress then either
open or close the out-carrier.
OUT-car clp lmts both ON extended limit
[Cause]: The out-carrier advance limit side close check sensors and the out-carrier
advance limit side open check sensors are both ON.
[Remedy]: Check the out-carrier advance limit side close check sensors (LX048,
LX049) and the out-carrier advance limit side open check sensors (LX04C,
LX04D).
XY-table clp lmt sensor has not come ON
[Cause]: The XY-table was clamped but the board clamp check sensors on the main
lifter did not come ON.
[Remedy]: Check the main lifter board clamp check sensors (X060, X061).
XY-table unclp lmt sensor has not turned OFF
[Cause]: The XY-table was clamped but the board unclamp check sensors on the
main lifter remained ON.
[Remedy]: Check the main lifter board unclamp check sensors (X062, X063).
XY-table unclp lmt sensor has not come ON
[Cause]: The XY-table was unclamped but the board unclamp check sensors on the
main lifter did not come ON.
[Remedy]: Check the main lifter board unclamp check sensors (X062, X063).
XY-table clp lmt sensor has not turned OFF
[Cause]: The XY-table was unclamped but the board clamp check sensors on the
main lifter remained ON.
[Remedy]: Check the main lifter board clamp check sensors (X060, X061).
XY-table dwn lmt sensor has not come ON
[Cause]: The XY-table was lowered but the main lifter lower limit check sensor did
not come ON.
[Remedy]: Check the main lifter lower limit check sensor (X067).
IN-car clp lmt sensor has not come ON
[Cause]: In the process of board transfer, with the XY-table at the ZL -
7 mm position, the in-carrier clamp limit sensors did not come ON.
[Remedy]: Check the in-carrier clamp close check sensors (LX042, LX043).
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-8 CP643E System Reference

OUT-car clp lmt sensor has not come ON
[Cause]: In the process of board transfer, with the XY-table at the ZL -
7 mm position, the out-carrier clamp limit sensors did not come ON.
[Remedy]: Check the out-carrier clamp close check sensors (LX048, LX049).
Lifter up 1/dwn lmt snsr err
[Cause]: During part placement a logic error occurred in connection with the
sensors used for checking the table height.
[Remedy]: During part placement the relevant sensors must be in the following
status.
Main lifter UP 1 check (X064) OFF
Main lifter DWN limit check (X067) ON
Main lifter middle overtravel (X066) ON
ST1 : Nozzle up/down error
ST1 : UP-lmt sensor ON
[Cause]: The station 1 nozzle was lowered but the station 1 cylinder upper limit
check sensor remained ON.
[Remedy]: Check the ST1 cylinder upper limit check sensor (X06A).
ST11 : Nozzle up/down error
ST11 : UP/DWN sensor error
[Cause]: The station 11 nozzle was lowered for part pickup but the upper limit
check and lower limit check sensors were both ON.
[Remedy]: Check the ST11 cylinder upper limit check sensor (X06B).
ST11 : Nozzle up/down error
ST11 : DWN-lmt sensor not ON
[Cause]: The station 11 nozzle was lowered for part pickup but the cylinder lower
limit check sensor did not come ON.
[Remedy]: There is a problem with the operation of the ST11 cylinder.
Check the cylinder. Exercise caution as it is possible that the station 11
part was not picked (missing).
ST2 Parts chk sensor err
[Cause]: There is a problem with the station 2 large parts check sensor.
Possible causes include light axis displacement between sides of the
sensor, or there may be a problem or broken wire with the light emitting
sensor itself.
[Remedy]: If there is a problem with the light axis adjustment between sides of the
sensor then readjust the light axis. If there is a problem with the light
emitting side of the sensor then either replace or readjust the position of
the sensor depending on the characteristics of the cause of the error.
PCB Transport Error: I_LIFT
Check board arrival sensor on the I_LIFT
[Cause]: Board transport on the in-conveyor was not carried out successfully.
[Remedy]: • Check the in-conveyor width.
• Make sure that board detection is working properly. Also confirm that
the board gap check sensor is ON when there is no board and OFF when
there is a board.
Part 5 Chapter 1 Errors and Countermeasures
Edition 1.0 5-1-9 CP643E System Reference