CP643 系统参考.pdf - 第81页
1.4 Nozzle Related Functions 1.4.1 Nozzle Check Function This function checks the production program to confirm that the appropriate nozzle is installed in each holder. This is done by performing a check on the nozzle di…

Insertion of Recovery Sequence
If a vision processing error occurs or there are no parts and the machine is set to carry
out a recovery operation, the recovery sequence will be inserted either 6 or 15 sequences
later.
If an error occurs between station 17 ~ 2 then recovery processing takes place at station 2
(this is done 6 sequences later however, this recovery processing does not include such
things as parts being discarded due to an emergency stop).
When an error occurs between station 3 ~ 10, recovery processing for such things as the
discarding of parts due to an emergency stop takes place at station 11 (15 sequences
later).
ST1
ST2
ST3
ST4
ST5
ST6
ST7
ST8
ST9
ST10
ST11
ST12
ST13
ST14
ST15
ST17
ST18
ST19
ST20
ST16
ST11: 15 sequences later
Recovery sequence
inserted at station 16
ST2: 6 sequences later
CP643S2009E
Part 2 Chapter 1 Basic Operation
Edition 1.1 2-1-23 CP643E System Reference

1.4 Nozzle Related Functions
1.4.1 Nozzle Check Function
This function checks the production program to confirm that the appropriate nozzle is
installed in each holder. This is done by performing a check on the nozzle diameter and
the back light disk size.
If a program has been transmitted to the foreground, then once program changeover has
been completed the Nozzle Check function is carried out when automatic operation
begins. If the nozzles installed in the previous production program have the same nozzle
diameter and back light disk size as the nozzles set to be used in the current production
program then no check is performed. If either the nozzle diameter or the back light disk
size are different then a check is performed. A check does not occur, for example, if a
white nozzle is replaced with a black nozzle, regardless of the nozzle size, etc.
It is necessary to set the appropriate Proper data item to enable this function. Make the
setting in the following manner:
[Proper]
136. Nozzle Check SW: This Proper data item determines whether or not the function
will be carried out.
(Example) 136. Nozzle Check SW Yes No
Yes: Mandatory nozzle check occurs
No: Mandatory nozzle check does not occur
When the Nozzle Check function is enabled a display like the one below will appear.
SET: Press this key to set the selected nozzle.
▲: Press this key to move the cursor up.
▼: Press this key to move the cursor down.
RETURN: Press this key to enter the nozzle center of rotation measurement command.
"UNSET" is displayed in red and "SET" is displayed in green.
Ready
SET ▲▼
CP643S2009A
RETURN
1
2
3
4
5
6
0.7 mm
1.0 mm
1.3 mm
2.5 mm
1.8 mm
5.0 mm
LUMI. DIAMNoz. Diam.
12 mmW
12 mmW
12 mmW
20 mmW
12 mmW
20 mmW
M/C
0.7 mm
1.0 mm
1.3 mm
3.4 mm
1.8 mm
5.0 mm
LUMI. DIAMNoz. Diam.
12 mmW
12 mmW
12 mmW
20 mmW
12 mmW
20 mmB
Program
Part 2 Chapter 1 Basic Operation
Edition 1.1 2-1-24 CP643E System Reference

1.4.2 Nozzle Center Measurement
In order to achieve high placing accuracy, the machine stores data on the center of
rotation, the amount of bend and other such data for each nozzle. The measurement of
these compensation data is called nozzle center measurement. Nozzle center
measurement is an indispensable part of being able to carry out highly accurate
placement.
This chapter provides an explanation of the nozzle center measurement.
(1) An Explanation of Nozzle Center Measurement
Nozzle center measurement carries out a measurement of the holder's rotation center.
The amount of bend in the nozzle, the nozzle tip diameter and the brightness of the
nozzle back light disk are also measured at the same time.
The distance from the rotation center to the nozzle tip is calculated. The nozzle bend is
compared to the amount of allowable bend (bend tolerance) and a decision is made.
When the nozzle is rotated 180° this yields the maximum amplitude of the nozzle tip and
thus the maximum amount of bend tolerance.
The nozzle center measurement is carried out twice on a single nozzle. The first
measurement looks at the current nozzle tip position. The second measure of the nozzle
tip position is carried out after the nozzle has been rotated 180°. During this second
measurement the maximum amplitude of the nozzle tip, the center and the amount of
nozzle bend are calculated.
Image processing for a single nozzle is carried out using both the wide view camera and
the narrow view camera since the camera resolution, field of vision and other such
variables are different.
Note: The narrow view camera (in effect the image is magnified by this camera) has a small area
image and is not used to perform nozzle center measurement on nozzles with a diameter
2.0 mm or greater.
Amount of allowable bend
Maximum amplitude
of the nozzle tip
Nozzle center of rotation
CP643S2010
Part 2 Chapter 1 Basic Operation
Edition 1.1 2-1-25 CP643E System Reference