5 -33 EPD8008100 Operation Chapter 5 5 Creating the PCB data 1. BASIC INFO . parameters 1. Comp . P ackage Refer to the description of “ 3.3.1 Standard chip components ” or “ 3.8 Setting the stick feeder component data ”…

5
-32
EPD8008100
Operation
Chapter 5
5
Creating the PCB data
3.4.2 SOP components
SOP components are registered with the parameters shown below.
SOP component parameters
27513-D8-00
6. SHAPE INFO.
Body Size X mm
Body Size Y mm
Body Size Z mm
Ruler Offset
Ruler Width
Lead Number
ReflectLL mm
LeadWidth mm
LeadPitch mm
:
:
:
:
:
:
:
:
:
6.40
10.15
2.10
2
2
8
0.50
0.45
1.27
5. VISION INFO.
Alignment Group
Alignment Type
AlignmentModule
Light Selection
Lighting Level
Comp. Threshold
Comp. Tolerance
Search Area mm
Datum Angle
Comp. Intensit
MultiCam. Marker
:
:
:
:
:
:
:
:
:
:
:
IC
SOP
Fore&Back&Las
Main + Coax
6/8
Normal
NotUse
55
30
5.00
0
1 .BASIC INFO.
Database No.
Comp. Package
Feeder Type
Required Nozzle
Feeder Set No.
Pos. Definition
Feeder Pos_X mm
:
:
:
:
:
:
:
Tape
32mmSticky
ForSOP10mm73
Automatic
704
7
-9.80
2. OPTION INFO.
FixCmpRef.
AIt.Cmp
Use feeder opt.
Comp. Group No.
Correct Pickpos
:
:
:
:
:
Yes
Not Use
0
0
0
3. PICK AND MOUNT INFO.
Pick Angle deg
Pick Timer
Mount Timer
Pick Height
Mnt Height
Pick Sequence
Mount Action
Mount Speed
PickupSpeed
XY Speed
Vacuum Check
Pick Vacuum
Mount Vacuum
Conv. Y Speed
:
:
:
:
:
:
:
:
:
:
:
:
:
:
4. DUMP INFO.
Dump Way
Retry Times
:
:
Dump POS
2
s
s
mm
mm
%
%
%
%
%
0
0.15
0.05
Normal
NORMAL
100
100
100
NORMAL CHK
FAST
0.0
0.5
10
10
1
2
3
4
5
6
41
42
43
44
45
46
47
48
49
50
51
11
12
13
14
15
31
32
61
62
63
64
64
65
66
67
21
22
23
24
25
26
27
28
29
n
NOTE
When setting the parameters shown in the sub-windows above, use the number keys to set
the parameters aligned on the right, while using the [INS], [DEL] or [Space] key to set
the parameters aligned on the left. However, there are some parameters which should be
set or optimized with the Adjust Assistant commands described later in “3.7” in this
chapter.
The displayed parameters differ slightly depending on the <3/1/A1 OPTION CONFIG>
settings.
Reference
To make parameter settings in the TRAY INFO. sub-window when using a stick feeder, also
refer to “3.8 Setting the stick feeder component data” in this chapter.

5
-33
EPD8008100
Operation
Chapter 5
5
Creating the PCB data
1. BASIC INFO. parameters
1. Comp. Package
Refer to the description of “3.3.1 Standard chip components” or “3.8
Setting the stick feeder component data” when stick feeders are used.
2. Feeder Type
Refer to the description of “3.3.1 Standard chip components” or “3.8
Setting the stick feeder component data” when stick feeders are used.
3. Required Nozzle
Select the optimum nozzle that matches the component size from among
the nozzle types for SOP components. (See “Nozzle table” listed in
Supplement in this manual.)
4. Feeder Set No.
Enter the feeder set number of the position at which the feeder is installed.
This parameter setting is unnecessary when the Use feeder opt. parameter
is set to “Yes.”
5. Pos. Definition
Set to “Automatic” when you set the Comp. Package parameter to “Tape”.
When using a stick feeder, refer to “3.8 Setting the stick feeder component
data” in this chapter.
6. Feeder Pos_X
Enter the position at which the head picks up the component from the
feeder. This parameter is skipped when the Pos. Definition parameter is set
to “Automatic”. For more details, refer to “3.8 Setting the stick feeder
component data” in this chapter.
2. OPTION INFO. parameters
For descriptions of the following OPTION INFO. parameters, refer to
“3.3.1 Standard chip components” in this chapter.
11. FixCmpRef.
12. Alt. Comp.
13. Use feeder opt.
14. Comp. Group No.
15. Correct Pickpos.

5
-34
EPD8008100
Operation
Chapter 5
5
Creating the PCB data
3. PICK & MOUNT INFO. parameters
21. Pick Angle deg
This parameter specifies the angle through which the mounter head rotates
to pick up a component on the feeder. This setting determines the orienta-
tion of the component (recognition reference) when it is recognized and
displayed on the vision monitor. The pickup angle for SOP components
must be specified so that their leads face the EW directions. Set this
parameter to 0° for horizontally long components in the loading position,
and set to 90° for vertically long components. Select the correct pickup
angle referring to the table below.
SOP component pickup angle
25507-C0-00
0 deg. 90 deg.
Loading position
Pickup angle
NS
E
W
N
S
WE
n
NOTE
For components having leads on the short sides like TSOP, set the Pick Angle deg
parameter to 0° when the loading position is vertically long, and to 90° when horizontally
long.
TSOP
23512-C0-00
0˚ 90˚
c
CAUTION
Pickup angle setting directly affects the recognition reference and mounting angle. Be
careful not to mistake 0° for 180° for horizontally long components in the loading
position and 90° for -90° for vertically long components.
22. Pick Timer, Mount Timer
These parameters specify the time duration (in seconds) for which the head
stays in the lowered position after detecting the reference pickup or mount
vacuum pressure when picking up or mounting a component. In most
cases, it is okay to set these parameters to “0.00”. If pickup or mount
operation is not stable, set a longer timer value.
c
CAUTION
Setting the Pick Timer and Mount Timer longer than necessary may have adverse
effects on the cycle time.