Using various functions
6
8.1 Multiplying the component data
To use the alternative component function, you should multiply the
component data to form two or more units of data. Each of the duplicated
component data becomes an alternative component.
1 Execute the <2/2/A1 OBJECT SELECTION> command.
The OBJECT SELECTION box then appears.
2 Select the PCB.
Select “PCB SELECTION” in the OBJECT SELECTION box and press the
[ENTER] key. A list of the registered PCB names then appears. Select the
PCB name, then select “QUIT” and press the [ENTER] key.
3 Execute the <2/2/A3 COMPONENT INF.> command.
The component information on the PCB data you have selected in Step 2
is displayed.
4 Select the component data to be multiplied.
Move the cursor to the component data line which you want to multiply.
5 Press the [ESC] key and select “MULTIPLY COMP.” from
the menu box.
Pressing the [ESC] key directly displays the COMP. INF. COMMAND menu
box, then select “MULTIPLY COMP.” and press the [ENTER] key. The
dialogue box then appears asking you how many pieces of data you want
to multiply by.
6 Enter the desired number you want to obtain, then execute
the command.
For example, when you want to obtain three pieces of data including the
original data, in other words two pieces of newly multiplied data, enter
“3” here. Then, press the [ENTER] key to execute this command. Two
pieces of multiplied data are displayed on empty lines on the Component
Info. screen.
Multiplying the component data
27634-C0-00
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 2/DATA_GENERATOR
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 2/DATA_GENERATOR
7
7
8
22
22
3
Component Name
Component Na
Machine
R1608
R2125
R3216
Machine
R1608
R1608
R1608
R2125
R3216
Feeder Type
8mmTape
8mmTape
8mmTape
8mmTape
8mmTape
MULTIPLY COMP. TIME
COMP.INF.COMMAND
MULTIPLY COMP.
Point.
No.
1
2
3
4
5
6
7
No.
1
2
3
4
5
6
7
Newly created
data
Original data
6
-53
EPD8013110
Operation
Chapter 6
6
Using various functions
7 Check the data.
You should check that the number of feeders including the multiplied
result does not exceed the number of feeders that can be installed on the
machine. To check, press the [ESC] key to display the COMP. INF.
COMMAND menu box, then select DATA CHECK and press the [ENTER]
key. When no alarm message appears, the data settings are okay.
8 Save the data and quit the command.
Press the [ESC] key to display the COMP. INF. COMMAND menu box
again, then select SAVE & QUIT and press the [ENTER] key.
If you do not want to save the multiplied component data, select EXIT
WITHOUT SAVING and press the [ENTER] key.
6
-54
EPD8013110
Operation
Chapter 6
6
Using various functions
6
8.2 Optimizing the feeder set positions
The feeder set position is not yet specified for the multiplied component
data, so you should execute the Data Generator command to designate the
optimum feeder set positions.
1 Select <2/2/A4 CONDITION SETTING> and press the
[ENTER] key.
The DATA GENERATOR CONDITION box then appears. Set the conditions
as explained below. After making settings, press the [ESC] key to close the
DATA GENERATOR CONDITION box.
BLOCK CONVERSION CONDITION
Set to No. (See 9. Data Optimization in Chapter 5 for more details.)
FEEDER SET CONDITION
Set to 4: ALL FEEDERS MOVE. This setting allows optimizing the
feeder set positions for all component data.
2 Execute the Data Generator command.
Press the [ESC] key to exit the current menu box, then select <2/2/A5
EXECUTE> and press the [ENTER] key.
3 Save the data.
After the optimization is completed, select <2/2/B0 SAVE & EXIT and
press the [ENTER] key. The optimized data will be saved.
Reference
When optimizing the feeder position only for newly multiplied data (with feeder set
numbers for other data left unchanged), enter 0 in the Feeder Set No. column of
theComponent Info.. Then, return to the DATA GENERATION CONDITION box
by executing <2/2/A4 CONDITION SETTING>, and set the FEEDER SET
CONDITION parameter to 2: NO SET POS. FEEDERS MOVE.