YV180X_Ope_E.pdf - 第290页
6 -55 EPD8013110 Operation Chapter 6 6 Using various functions 8.3 Alternative component number After multiplying the component data, check that the correct number is input for the “ Alt.Cmp ” parameter in the component …

6
-54
EPD8013110
Operation
Chapter 6
6
Using various functions
6
8.2 Optimizing the feeder set positions
The feeder set position is not yet specified for the multiplied component
data, so you should execute the Data Generator command to designate the
optimum feeder set positions.
1 Select <2/2/A4 CONDITION SETTING> and press the
[ENTER] key.
The DATA GENERATOR CONDITION box then appears. Set the conditions
as explained below. After making settings, press the [ESC] key to close the
DATA GENERATOR CONDITION box.
• BLOCK CONVERSION CONDITION
Set to “No”. (See “9. Data Optimization” in Chapter 5 for more details.)
• FEEDER SET CONDITION
Set to “4: ALL FEEDERS MOVE”. This setting allows optimizing the
feeder set positions for all component data.
2 Execute the Data Generator command.
Press the [ESC] key to exit the current menu box, then select <2/2/A5
EXECUTE> and press the [ENTER] key.
3 Save the data.
After the optimization is completed, select <2/2/B0 SAVE & EXIT” and
press the [ENTER] key. The optimized data will be saved.
Reference
When optimizing the feeder position only for newly multiplied data (with feeder set
numbers for other data left unchanged), enter “0” in the Feeder Set No. column of
the“Component Info.”. Then, return to the DATA GENERATION CONDITION box
by executing <2/2/A4 CONDITION SETTING>, and set the FEEDER SET
CONDITION parameter to “2: NO SET POS. FEEDERS MOVE”.

6
-55
EPD8013110
Operation
Chapter 6
6
Using various functions
8.3 Alternative component number
After multiplying the component data, check that the correct number is
input for the “Alt.Cmp” parameter in the component information.
1 Open the Component Info. screen.
Open the Component Info. screen of the PCB data for which you per-
formed component data multiplication in the <2/1/EDIT_DATA> mode.
2 Check the alternative component number.
Line up the cursor with the component data designated as the alternative
component, and check that the correct number is entered in “Alt.Cmp.” on
the BASIC INFO. sub-window.
For example, when No. 1, 2 and 3 in the component information are
specified as an alternative component group, check that “2” is entered in
“Alt.Cmp.” for No.1, “3” for No. 2, and “1” for No. 3. This means that the
alternative component for No. 1 is No. 2, that for No. 2 is No. 3, and that
for No. 3 is No. 1, just like making a loop of 1→2→3→1 in the alternative
component group.
Checking the alternative component number
27635-C0-00
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
PCB :
OBJ :Component Info.
No.
1
2
3
4
5
6
7
COMPONENT NAME
R1608
R1608
R1608
COMMENT
2.OPTION INFO.
Alt. Cmp
:
2
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
PCB :
OBJ :Component Info.
No.
1
2
3
4
5
6
7
COMPONENT NAME
R1608
R1608
R1608
COMMENT
2.OPTION INFO.
Alt. Cmp
:
3
<<<APPLICATION>>> 2/DATA/M
<<MODE>> 1/EDIT_DATA
PCB :
OBJ :Component Info.
No.
1
2
3
4
5
6
7
COMPONENT NAME
R1608
R1608
R1608
COMMENT
2.OPTION INFO.
Alt. Cmp
:
1
Check her
e

6
-56
EPD8013110
Operation
Chapter 6
6
Using various functions
6
8.4 Component switching flow
In the Alternative component function, component feed is switched in the
operation flow explained below.
When the components in the current feeder run out, the machine allows
automatic switching to the alternative component feeder without interrupt-
ing operation. When one cycle using alternative components is complete,
the machine stops and a message asking you to resupply the components
then appears. In the case of components supplied from a nonstop feeder
system (option), the machine can continue operation by resupplying the
components during operation.
Operation flow
23620-C0-00
Out of components
Automatic operation
NO
YES
YES
NO
Machine stops
E87
NO COMPONENT FOR USE
All components in alternative loop are not available.
This can be caused by the following:
-Pick up or recognition error happened.
-Component counter reached specified number.
Refill the components or check feeders and run again.
Automatically switches
to alternative
components
Is one cycle using
alternative component
group complete?
Were components
resupplied during
operation?