YV180X_Ope_E.pdf - 第300页

6 -65 EPD8013110 Operation Chapter 6 6 Using various functions 9.2 Using the pattern matching data Pattern matching can be used in the same wa y as the fiducial marks. In this case, enter the mark No. registered as the p…

100%1 / 307
6
-64
EPD8013110
Operation
Chapter 6
6
Using various functions
6
Search Area setting
23628-C0-00
Search area
Search area is too large, so
other marks are recognized.
Search area is too small,
so the target pattern is
not inside the search area.
Pattern Size X
The size in pixels (1 to 512) of the registration pattern along the X
direction (horizontally across screen). This value is automatically input
during pattern registration.
Pattern Size Y
The size in pixels (1 to 512) of the registration pattern along the Y
direction (vertically across screen). This value is automatically input
during pattern registration.
Offset X
The deviation (offset) in pixels (-256 to +256) along the X direction
between the center of the registration pattern and the position being
searched for. This value is automatically input during pattern registra-
tion.
Offset Y
The deviation (offset) in pixels (-256 to +256) along the Y direction
between the center of the registration pattern and the position being
searched for. This value is automatically input during pattern registra-
tion.
q Quit the Adjust Assistant.
To quit, execute the EXIT command and you will return to the Mark Info.
screen.
w Save the data.
Press the [ESC] key to exit the current edit screen, then select <2/1/D8
SAVE PCB DATA> or <2/1/D0 SAVE PCB DATA & EXIT> and press the
[ENTER] key.
6
-65
EPD8013110
Operation
Chapter 6
6
Using various functions
9.2 Using the pattern matching data
Pattern matching can be used in the same way as the fiducial marks. In this
case, enter the mark No. registered as the pattern in the locations where
mark No. should be input. (The figure below shows an example when using
pattern matching as PCB fiducial marks.
Example of using pattern matching
27639-C0-00
PCB: OBJ :PCB Info.
MARK
5
1
1
6
X/X1
0.00
240.00
10.00
5.00
0.00
15.00
0
0
Y/Y1
0.00
175.00
10.00
5.00
0.00
5.00
0
0
MRK2
6
0
X2
1.6
230.00
215.00
Y2
160.00
77.50
Skip?
-1
Use
NotUse
NotUse
NotUse
Exec
Check
UseAlign
PcbFixDevice
Pre-FixTimer
Trans-Height
Conv. Timer
Precede Pick
Conv. Y Speed
Pin+PushUP
0.0
15
0.0
Not Use
FAST
Not Use
Not Use
Group
Not Use
Mount
Vacuum Check
Alignment
PCB Origin
PCB Size
PCB Fiducial
BLOCK Fiducial
PCB Badmark
BLOCK Badmark
PCB Comment
Pcb/Schedule/Block
Unloader Count/Max
Set to "Use".
Enter mark No. registered as pattern in mark information.
Supplement
1. Nozzle table ......................................................................... S-3